SA_HF_intern_0194307-02_eng - 第12页
2 Safe ty What to do Be fore Starting Servicing Work. .. SIPL ACE HF-Ser ies Safety Instruction s for the Comp ressed Ai r Supply 2-6 0019 43 07- 02 Is su e 1 1/ 2004 Copy ri gh t © 2 004 S ie m ens 2.2 Wha t to do B efo…

SIPLACE HF-Series
Safety Instructions for the Compressed Air Supply
Safety
Safety Instructions
2
Copyright © 2004 Siemens 00194307-02 Issue 11/2004 2-5
Exchanging components
End all placement operations on the placement system.
Shut down the Windows NT operating system correctly, otherwise problems may occur when restarting or data may
be lost.
Switch the placement system off at the main switch.
Disconnect the placement system from the main power supply.
Switch off the machine and attach warnings signs to indicate that service work is in progress.
2.1.5 Safety Instructions for the Compressed Air Supply
CAUTION
When the machine is switched on, do not use the shutoff valve to interrupt the compressed air supply for more than 30
minutes. If you need to shut off the pneumatic system for longer, in order to carry out maintenance or servicing work, you
must switch the placement system off at the main switch and disconnect it from the power supply.
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury!

2
Safety
What to do Before Starting Servicing Work...
SIPLACE HF-Series
Safety Instructions for the Compressed Air Supply
2-6
00194307-02 Issue 11/2004 Copyright © 2004 Siemens
2.2 What to do Before Starting Servicing Work...
Switch off the machine and secure to prevent unauthorized reactivation.
End all placement operations on the placement system.
Disconnect the component table of the gantry concerned, if necessary.
Switch the placement system off at the main switch.
Wait until the operating system has shut down and the UPS has switched off.
Disconnect the placement system from the main power supply.
Disconnect the placement system from the compressed air supply.
Switch off the motor contactor in the power supply and secure the operating lever with a padlock.

SIPLACE HF-Series
Safety Instructions for the Compressed Air Supply
Safety
What to do Before Starting Servicing Work...
2
Copyright © 2004 Siemens 00194307-02 Issue 11/2004 2-7
1
3
2
Turn the operating lever (1) counterclockwise.
Use the screwdriver to push the locking lug (2) out of the
operating lever (1).
Secure the operating lever with a padlock (3).
Alternatively: Attach warning signs.
If a machine can be locked, it must be. However, there are situations where energy isolating devices can not
accommodate locks. In these cases, the energy isolating devices must be tagged to warn employees that the machine is
de-energized for servicing. The tag must be securely fastened, it must be placed in a position visible to all and it may only
be removed by the person who attached it.