SA_HF_intern_0194307-02_eng - 第23页
SIPL ACE HF-Ser ies Replacing the Gantry [030 06781-xx ] Serv ice Gan tri es 3 Copy ri ght © 200 4 S ie m ens 0019 43 07- 02 Is su e 1 1/ 2004 3-9 2 1 2 Do not tighten the fastenin g screws ye t! Lift the far end of …

3
Service
Gantries
SIPLACE HF-Series
Replacing the Gantry [03006781-xx]
3-8
00194307-02 Issue 11/2004 Copyright © 2004 Siemens
1
3
2
Carefully rub the following contact surfaces with a dressing
stone (oil stone) and wipe clean with a cloth and ethanol.
1. Magnet support
2. Contact surfaces of the 4 guide slides
3. Contact edges of the 4 guide slides
Enlist the help of a second strong person. Lift the gantry up to
the guide slides and secure the gantry at the top with two
screws (M4 x 14).
Then loosely screw in the remaining screws. Observe the
correct screw lengths.

SIPLACE HF-Series
Replacing the Gantry [03006781-xx]
Service
Gantries
3
Copyright © 2004 Siemens 00194307-02 Issue 11/2004 3-9
2
1
2
Do not tighten the fastening screws yet!
Lift the far end of the gantry (1) so that the gantry rests on the
contact edges of the top guide slide (2).
Tighten the top fastening screws.
Then tighten all 16 fastening screws with the aid of the special
torque wrench ("Bruchsal version") (9.5 N).

3
Service
Gantries
SIPLACE HF-Series
Replacing the Gantry [03006781-xx]
3-10
00194307-02 Issue 11/2004 Copyright © 2004 Siemens
1
With the aid of a 1/100 plastic thickness gauge, check the gap
between the portal contact edge and the guide slide (1). The
gantry must lie flush with the guide slide, leaving no room in-
between for the thickness gauge.
If this is not the case, dismantle the gantry and clean the
contact surfaces again thoroughly (with the dressing stone).