00194307-02 Issue 11/2004 Copyright © 2004 Siemens
Adjust the trailing cable console (1) and pressure plates, where
necessary.
Fix the two pressure plates (6) and the trailing cable console (1)
with Loctite 242.
Tighten the fastening screws for the trailing cable console (1)
crosswise.
SIPLACE HF-Series
Replacing the Trailing Cable [03013940-xx]
Service
Gantries
3
Copyright © 2004 Siemens 00194307-02 Issue 11/2004 3-21
5
1
3
2
Reconnect the cooling tubes to the Y-axis motor.
Install the 3 pressure plates (1) on the gantry and head mount
(2).
Install the head board (3). Make sure you do not lose the
contact disks or spacer bolts.
Plug in all connections/terminals. Observe the correct connector
assignment.
Fasten new cable ties at the original points.
Replace all cover plates.
3
Service
Gantries
SIPLACE HF-Series
Replacing the Y-Drive (Primary) [03006768-xx]
3-22
00194307-02 Issue 11/2004 Copyright © 2004 Siemens
3.1.3 Replacing the Y-Drive (Primary) [03006768-xx]
Disassembly
2
3
1
3
Dismantle the gantry and put it in a suitable place (1).
Remove the cable ties holding the connection cable.
Remove the proximity switch mount (2) and proximity switches.
Undo the 16 fastening screws (3). Make sure you do not lose
the insulating plates underneath the screws. These must be
replaced after completing service work.
CAUTION