SA_HF_intern_0194307-02_eng - 第51页

SIPL ACE HF-Ser ies Replacing the X -axis Read Head [ 03 006472] Serv ice Gan tri es 3 Copy ri ght © 200 4 S ie m ens 0019 43 07- 02 Is su e 1 1/ 2004 3-37 Installation 4 3 1 2 1. Head mou nt - front vi ew  Clean the r …

100%1 / 76
3
Service
Gantries
SIPLACE HF-Series
Replacing the X-axis Read Head [03006472]
3-36
00194307-02 Issue 11/2004 Copyright © 2004 Siemens
Disassembly
4
3
1
2
1. Head mount - front view
2. Read head
3. Fastening screws
4. Grub screws for fastening
CAUTION
Do not loosen or unscrew the grub screw (4).
Unthread the connection cable as far as the read head (2).
Undo the three screws (3) fastening the X-axis read head (2)
and carefully lift off the read head.
SIPLACE HF-Series
Replacing the X-axis Read Head [03006472]
Service
Gantries
3
Copyright © 2004 Siemens 00194307-02 Issue 11/2004 3-37
Installation
4
3
1
2
1. Head mount - front view
Clean the reading surface of the read head with a cloth and
ethanol or with a Q-tip.
Loosely fasten the read head (2) with three screws (3).
The read head must be aligned with a 0.4 mm gap to the scale.
Use the corresponding thickness gauge (plastic).
Tighten the fastening screws.
Reconnect to the electricity supply.
Make sure that the cables do not rub against anything. Fasten
them with cable ties.
CAUTION
Make sure that the axes can be moved without damaging the cables.
Check the track signals with an oscillograph.
3
Service
Gantries
SIPLACE HF-Series
Replacing the X-axis Read Head [03006472]
3-38
00194307-02 Issue 11/2004 Copyright © 2004 Siemens
3.1.5.1 Adjusting the Grub Screw
Adjusting the grub screw
Long Allen wrench size 1.5 for the grub screw on the read head
Varnished grub screw or locking varnish (Loctite No. 241)
4
3
1
2
Use the long Allen wrench (no ball head) to loosen the grub
screw (4) on the read head (2). The grub screw applies
pressure to the head mount and prevents unwanted movement
of the read head.
Remove the grub screw (4) and apply a little locking varnish
(Loctite No. 241) to it.
Screw the grub screw back in (4) until you are almost at the end
of the thread.
Install the read head (2) with the three fastening screws (3) so
that there is a gap of 0.4 mm between the read head and the
scale. Use the corresponding thickness gauge (plastic).
Tighten the grub screw (4) until you feel a slight resistance (not
too tight).
The read head is now fastened correctly.