Introduction(CP45FV) Eng.pdf - 第58页
Samsung Component Placer CP45FV Series Intr oduction supply power to the power systems such as a motor. To cut off the power supply, press the red switch. Safeguard override key switch (Front / Rear) This is used for t…

Panel Operations
Chapter 4. Panel Operations
4-1
4.1. Switching of Operation Panel
Emergency switch
Ready button
Start button
Stop button
Reset button
Front Feeder CHG. button
Front/Rear select switch (Option)
Main start switch
Safe Overide Key switch
Main switch
Figure 4-1. Operation Panel
Switching operation on the operation panel is described below.
Main switch
Has a function of supplying or stopping the main power to the machine. Power is
supplied to a controller by turning the switch. A power lamp is lighted and a working
screen is shown on the programming monitor after a short delay. During the initial
stage, power is not turned on for the drivers such as motor. The power should be
turned off only after terminating the MMI. If the power is suddenly turned off, the
data and the main body may be damaged and the machine malfunction may occur at
the next power up.
Warning
If power supply is cut off suddenly, it could result in the
damage of data and machine.
And the machine might be damaged due to abnormal
operation when power is supplied again.
Before turning off power, be sure to end the MMI, turn off
the main switch, then turn on the main switch after 5-10
seconds.
Main start switch (IO switch)
Power is supplied by first pressing the green switch of a main start switch in order to

Samsung Component Placer CP45FV Series Introduction
supply power to the power systems such as a motor. To cut off the power supply,
press the red switch.
Safeguard override key switch (Front / Rear)
This is used for the door interlock bypass. It is used limitedly only when performing
initial setting or maintenance of the equipment.
Warning
The safeguard override key switch must be used by the
designated responsible personnel. It must be carefully
used for machine operation.
<Ready> button
This is a switch for initiating the operation of this machine. The power is supplied to
the driving systems such as motor. It is used to put the machine into the standby
status after power-up. <EMG (emergency stop)> switch can be pressed to release the
standby state.
<Start> button
This is a switch for initiating the operation of this machine. Automatic operation is
initiated if this switch is pressed.
This switch can be activated for the following cases..
Temporary stop status of operation by <Stop> switch during automatic operation
Error stop status that can be restarted
Warning
Pressing the Start switch without checking the presence
of worker nearby could cause injury. Be sure to check if
there is any worker near the machine before pressing the
Start switch.
<Stop> button
This is a switch for temporary stopping of the operation. Automatic operation of this
machine is temporarily stopped if this switch is pressed. If this switch is pressed
while the placement is in progress, the operation is stopped after the present operation
is completed. This switch can also be used for turning off alarm sound due to an error.
<Reset> button
This is a switch for terminating the operation of this machine. Automatic operation of
this machine is forcefully terminated if this switch is pressed. This switch is used for
deactivating either temporary stop status that had been activated by pressing the
<Stop> switch or the stop status due to an error. The <Reset> switch cannot be
activated during automatic operation of this machine.
<Feeder change> button
When this switch is pressed, the XY gantry moves to a safe position so that the feeder
can be replaced.
EMG (Emergency Stop) switch
This is an emergency stop switch. Operation of this machine is immediately
suspended if this switch is pressed in case of an emergency. Supply of all powers
except for the power to a computer is ceased. The emergency stop status can be
released by turning the <EMG> switch in the direction of the arrow and pressing the
4-2

Panel Operations
4-3
<Stop> and <Reset> switch.
Front/Rear select switch, Front/Rear panel lamp(Optional)
It is the switch that determines which one of the front operation panel and rear
operation panel will have the control authority. Whether or not the corresponding
operation panel has the control authority depends on the status of this switch. (Start,
Feeder change, Keyboard, Mouse). The control authority according to the switch
status is as shown on the following table.
The front
panel select
switch status
The rear
panel select
switch status
Front lamp
status
Rear lamp
status
Control Authority
OFF OFF OFF OFF None
ON OFF ON OFF Front Operation Panel
OFF ON OFF ON Rear Operation Panel
ON ON BLINK BLINK None
4.2. Standards for Lighting Signal Light
This machine comes with a signal light for indicating the present status of the machine.
The signal light indicates the following;
Lighting of a red lamp
Indicates the stop status through self-diagnosis of the system. Warning sounds ring
continuously and messages are indicated as the red lamp is lighted.
Flashing of a red lamp
Indicates either the pressing of the <EMG> switch or the emergency stop status
through self-diagnosis of the system. Warning sounds ring continuously and
messages are indicated as the red lamp is flashed.
Lighting of a yellow(or blue) lamp
Indicates the standby status of operation.
Flashing of a yellow(or blue) lamp
Indicates either component shortage in the tray feeder or adsorption error. Warning
sounds ring continuously and messages are indicated as the yellow(or blue) lamp is
flashed.
Lighting of a green lamp
Indicates that this machine is currently being operated automatically.
Flashing of a green lamp
Indicates temporary stop status. Automatic operation can be resumed by pressing the
<Start> switch.