Introduction(CP45FV) Eng.pdf - 第65页
Sensor Functions 5-3 5.3. Board Detection Sensor There are five board detection sensors insta lled on the PCB take-in and take-out paths of the conveyor . Input Sensor W ait Sensor Place Sensor Quick Load Sensor Output S…

Samsung Component Placer CP45FV Series Introduction
5.2. Feeder Unlock Sensor
Feeder unlock sensors are installed at the front and rear of this machine. The system
comes into the emergency stop status if the feeder is not installed correctly at the feeder
base. In this case, verify that the feeder is installed properly.
Front Feeder Unlock Sensor (Ligh
t
receiving section)
Front Feeder Unlock Sensor (Ligh
t
emitting section)
Rear Feeder Unlock Sensor (Ligh
t
emitting section)
Rear Feeder Unlock Sensor (Ligh
t
receiving section)
Caution
If the feeder loose sensor is cancelled arbitrarily, the head
and the feeder might collide as a loose feeder cannot be
sensed.
Do not cancel the feeder loose sensor arbitrarily.
5-2

Sensor Functions
5-3
5.3. Board Detection Sensor
There are five board detection sensors installed on the PCB take-in and take-out paths of
the conveyor.
Input Sensor
Wait Sensor
Place Sensor
Quick Load Sensor
Output Sensor
Figure 5-2. Installing Position of PCB Detection Sensors
The positions and functions of each sensor are as follows.
Input Sensor: Detects take-in of PCB into this machine from the previous process.
Wait Sensor: Detects PCB in the Wait buffer (at the wait position).
Place Sensor: Detects PCB in the place buffer (at the placement position).
Quick-Load Sensor: Detects PCB completed placement so that the PCB in the wait
buffer can be loaded quickly.
Output Sensor: Detects PCB taken out from the machine.
The conditions for detection may vary depending on the installation method, distance,
and angle and location of each sensor as well as due to dust, external light, shape, and
color of the board. Therefore, sensitivity of a sensor should be adjusted by using the
actual board that will be used. When adjusting the sensitivity of the board detecting
sensor, if there is no PCB, neither the red nor the green LEDs shall be turned on. The
“lightness/darkness“ adjusting screw shall always be turned to the “L” side.
If there is a PCB, turn the sensitivity adjusting screw clockwise so that both the red and
green LEDs are turned on.
If the “lightness/darkness“ adjusting screw is not turned to the “L” side, only the red LED
is turned on.
For reference, the sensitivity of the input sensor, quick load sensor and output sensor
cannot be adjusted.

Samsung Component Placer CP45FV Series Introduction
Sensor Window
Sensitivity
Red LED
Green LED
Lightness/Darkness Adjusting Screw
Figure 5-3. Sensor Adjustment
Warning
Adjusting the sensor or correcting an error while the
machine is ready could result in personal injury.
Be sure to adjust the sensor or correct an error in the stop
status (idle mode) after canceling the ready status.
5-4