Introduction(CP45FV) Eng.pdf - 第78页
Samsung Component Placer CP45FV Series Intr oduction Figur e 6-10. Light Path Contr ol The optimum lighting direction for each com ponent is shown in the following figure. CB 커넥터의 경우 일반적인 부품 General Component GA인 경우 CBGA…

Module Function
6-9
on a lighting system that moves to the Z axis. When it is not in use, it stays up, and when
a component is recognized, the device comes down and illuminates the component. This
light is used to illuminate the ball during BGA component recognition, and it is also used
to emphasize the outline of Chip and IC components. It is possible to control steps
between 0 - 15.
6.6.3.2. Outer Lighting
The outer light is a light illuminating obliquely from the front of the component. This
light exists between the lens and the mirror of the CCD camera and it illuminates the
entire component. It is used for most components and it is possible to control steps
between 0-15.
6.7. Upward Vision Unit
The upward vision unit can recognize the general and Odd-type components, and also has
a digital lighting controller. Thus, safe and accurate recognition and placement is possible.
LED
Cover glass
Camera
Figure 6-9. Upward vision unit
6.7.1. Lighting path control
The optimum lighting conditions are achieved by selecting the lighting in the desired
direction according to the component to be measured as shown in the following figure.

Samsung Component Placer CP45FV Series Introduction
Figure 6-10. Light Path Control
The optimum lighting direction for each component is shown in the following figure.
CB 커넥터의 경우
일반적인 부품
General Component
GA인 경우
CBGA
Connectors
Figure 6-11. Optimum Lighting Direction for Each Component
The 3-stage lighting is applied to CBGA process as shown below.
Figure 6-12. Lighting Application for CBGA Process (Left: general; Right: 3-stage lighting)
As shown in “Figure 6-12“, the exact shape of a ball can be recognized by using the side
lighting.
6-10

Module Function
6-11
6.8. ANC (Auto Nozzle Changer)
ANC is fixed to the machine. The fixed type ANC is composed of the alignment part for
aligning the nozzle and the shutter part for holding and guiding the nozzle.
Align
Open/Close Cylinder
Shutter
Limit Sensor
Speed Control Valve
Figure 6-13. 37-Hole ANC (fixed to the machine)
ANC is an automatic nozzle-switching device that detaches or attaches as the nozzles
are switched to accommodate the component type during the process. The shutter is
opened or closed by a cylinder. Whether the shutter is currently open or closed can be
confirmed by a limit sensor attached to the cylinder.
The connectors for the sensor and the air pressure line are connected to the connector
panel attached to the feeder station cover. Air pressure is generally set 0.45 – 0.55
MPa. The air flows in through the main inlet located at the bottom of the rear side of
the machine, and is used for operating the head, ANC, etc.
Open/close speed of the ANC shutter is controlled by a speed control valve attached
to the cylinder. Up to 36 nozzles can be attached to ANC, and the time duration for
switching of the nozzle is about 0.5 seconds.
As the nozzle of ANC can be set easily at any position, it is possible to either increase
pickups rate or to shorten the placement time by reducing the frequency of the nozzle
switching.
Because ANC is located at the inside of the feeder base, the number of able feeders is
not reduced even when ANC is installed. However, if the movable type ANC is
installed, it can be installed exclusively on the rear feeder base and it occupies 5 slots.
Caution
Operating the shutter while a finger is inserted in the ANC
could result in severe injury. Do not insert a finger into the
ANC Hole.