Transfer & Installation Procedure
7-7
with the connector at the left of the inside of the machine.
19. Following level adjustment, connect the keyboard and mouse to the top of the front
cover and install the teaching box at the bottom right of the front panel.
Figure 7-6. Installing the monitors and signal light
20. Ensure that the machine power supply has been correctly connected to suit the use of
the machine.
Reference
Rating: Single phase, 60Hz, 220 Volt, voltage variation ± 5% (10Volt).
Power consumption: CP40(2.6 KVA), CP45(2.6 KVA)
Grounding: Based on 3
rd
class grounding, the Mega Test value shall be less than 100
Ω between the ground wire and the machine.
AVR: The AVR is a basic option. It is recommended to have the capacity margin at
more than 20%.
Caution
When taking a single phase power from a 3 phase power
source, any incidental trip of power may cause phase
distortion, which may lead to damage of the machine. To
avoid such an occurrence, total use of single phase power
is recommended to be less than 40% of the total capacity
(Kw).
21. Insert the power supply cable into the AC power input terminal. At this time, the
power should not be turned on.

Samsung Component Placer CP45FV Series Introduction
Figure 7-7. AC power input connection
22. Install the Standard Dump Box once the proper location for it has been determined.
23. Install the upward camera on a feeder base (rear feeder lane #42). At this time,
tighten the adjusting bolt completely. Furthermore, remove the dust cover on the
camera glass after installation has been completed to avoid any contamination.
24. Connect the pneumatic air line to the Main Air Inlet.
Figure 7-8. Supplying pneumatic air to the Main Air inlet
25. Turning the knob of the regulator, adjust the air pressure to 0.45 ~ 0.55 MPa. (The air
consumption of the machine is max. 150 Nℓ/min.)
7-8

Transfer & Installation Procedure
7-9
Caution
Oil leaka
g
e into the pneumatic pipe line due to the
compressor being too old may cause fatal errors in each
machine. Foreign matters like chips and burs remain inside
the pipe once piping work is completed. Therefore, it is
recommended to flush the piping with the pipe ends being
covered with a clean cloth. If the cloth remains clean and
there is no sign of contamination, after a series of flushings,
then connect the pneumatic pipe to the machine. Check if
the air dryer has been installed to prevent moisture
condensing inside the pipe.
26. Referring to the following, check communication interface between the previous
process machine and the next process machine.
Start input signal (Cable No.:①〔+),②〔-))
The input signal is transmitted from the next process machine, and the voltage
measured at most of the input signal terminals is about 20~22V.
Ready output signal (Cable No.:③ , ④ )
The output signal is transmitted from all of the process machines. In general, at most
output signal terminals, the measured resistance is 0Ω when the output signal comes
out from the terminal while it is ∞Ω when there is no output signal.
IN
OUT
①
②③
④
①
②
③
④
Output Terminal
Input Terminal
DC24V〔+〕
①
②
③
④
DC 0V〔-〕
Figure 7-9. Interface between previous and next process machines