MAN00000772_SI-G200BB_SVCPDFA.pdf - 第163页
HLGB-10105-01 Calibration Data Load [Necessary jigs] • C alibrat i on data FD [Procedure] < When performing calibration for the front head > < When performing calibration for the front head > If there’ s no d…

HLGB-10104-01
Change in User Level
To display a screen used for calibration, it is necessary to change user level. This section describes a
procedure to change user level.
[Procedure]
Click the button on the left
upper of the screen.
USER LEVEL screen is displayed.
Click the SERVICE button.
Enter the password and click the Set
button.
To display the calibration screen, it is necessary
to change the USER LEVEL to
[MAINTENANCE] or [SERVICE].

HLGB-10105-01
Calibration Data Load
[Necessary jigs]
• Calibration data FD
[Procedure]
< When performing calibration for the front head >
< When performing calibration for the front head >
If there’s no description in Calib.ini, refer to the following.
Same value as MOUNT_HEIGHT in NOZZLE_S_TYPE_G = head.ini
A value obtained by subtracting “3” from MOUNT_HEIGHT in NOZZLE_T_TYPE_G = head.ini
A value of H of [FixedCamera] POS_XYH in FIXED_INSP_HEIGHT = head.ini
Use a FD having a same No as the ball point
jig.

HLGB-10105-01
Calibration Data Load
<When the indicated jig No is different
form jig No to be used>
Press the Use another jig button.