MAN00000772_SI-G200BB_SVCPDFA.pdf - 第167页

HLGB-10106-01 Origin Return of the Unit (M/C ORG) < Operating seque nce of origin return > Origin return of H/F axis Origin return o f X/Y axis, RT/RN axis T urn OFF the interlock key when removing the alternation …

100%1 / 712
HLGB-10106-01
Origin Return of the Unit (M/C ORG)
[Procedure]
Check that two plungers are
withdrawn.
Turn RT axis to a position where inner
shaft upper end matches H axis
pusher.
It is unnecessary to raise the alternation carts.
For any malfunction of the unit during origin
return, prepare to immediately press the
emergency stop switch.
HLGB-10106-01
Origin Return of the Unit (M/C ORG)
< Operating sequence of origin return >
Origin return of H/F axis
Origin return of X/Y axis, RT/RN axis
Turn OFF the interlock key when removing the alternation cart after origin return or when opening the
door to perform working.
Since the function of the area sensor is enabled when the interlock key is ON, the unit is in the emergency
stop state if your hand etc is put into the unit.
Similarly, when the alternation cart is removed from the unit with the interlock being ON, the unit is in
the emergency stop.
HLGB-10201-01
RT Axis Origin Position Setup
Perform this working on both heads on the front side and rear side.
[Necessary jigs]
RT origin jig
[Procedure]
Click in an order of M/C SETUP
menu M/C MAINTENANCE tab
Calibration button.