MAN00000772_SI-G200BB_SVCPDFA.pdf - 第170页

HLGB-10201-01 RT Axis Origin Position Setup Be careful not to enter H axis OT a nd rotate the RT axis.

100%1 / 712
HLGB-10201-01
RT Axis Origin Position Setup
Click the Machine Setup button on the
CALIBRATION screen.
Click the RT Axis Home button on the
Machine Setup screen.
Click the XY button on the RT Axis
Home screen.
Click the Jog Move button in the move
mode.
Press the cursor key to move the head
to a position where working is easily
performed.
Press the Return button after the
head moves to close the XY axis
screen.
HLGB-10201-01
RT Axis Origin Position Setup
Be careful not to enter H axis OT and rotate the
RT axis.
HLGB-10201-01
RT Axis Origin Position Setup
Press the Save button with the servo ON.