MAN00000772_SI-G200BB_SVCPDFA.pdf - 第177页

HLGB-10203-01 Acquiring Mounting Stro ke Setu p W hen installing the nozzle, insert it while slowly turning. After inserting the nozzle, check that it is not drawn out by pulling downward. Click in an order of M/C SETUP …

100%1 / 712
HLGB-10203-01
Acquiring Mounting Stroke Setup
Perform this working on both heads on the front side and rear side.
[Necessary jigs]
Calibration plate jig
Jig positioning pin
Length reference nozzle jig
Thickness gauge (t=0.03 mm)
[Procedure]
HLGB-10203-01
Acquiring Mounting Stroke Setup
When installing the nozzle, insert it while
slowly turning.
After inserting the nozzle, check that it is not
drawn out by pulling downward.
Click in an order of M/C SETUP
menu M/C MAINTENANCE tab
Calibration button.
Click the Machine Setup button on the
CALIBRATION screen.
Click the Acquiring mounting stroke
button on the Machine Setup screen.
HLGB-10203-01
Acquiring Mounting Stroke Setup
Click the XY button on the Acquiring
mounting stroke screen.
XY Axis screen is displayed.
Click the Jog Move button.
Press the cursor key to jog move the
head unit onto the calibration plate
jig.
Click the Return button to return to
the Acquiring mounting stroke screen.
Click the R.H button on the Acquiring
mounting stroke screen.
RN/H Axis screen is displayed.
Click the Jog Move button.
Press the downward cursor key and
lower until the gap between the length
reference nozzle jig and calibration
plate jig becomes 0.03mm.
Slowly lower by Jog slow move while checking
the nozzle position so that the length reference
nozzle jig does not collide he calibration plate
jig.