HLGB-10302-01 Fixed Camera Light Calibration Press the [ST ART] butto n on the oper ation p an el.

100%1 / 712
HLGB-10302-01
Fixed Camera Light Calibration
Calibration procedure of fixed camera upper light will be described here as an example.
Also perform calibrations of fixed camera middle light/fixed camera lower light/fixed camera coaxial
light by the same procedure.
[Necessary jigs]
Fixed camera light calibration jig
[Procedure]
Click the Light Calibration button on
the CALIBRATION screen.
Click the Fixed Camera Upper Light
button on the Light Calibration
screen.
When performing calibrations of fixed camera
middle light/fixed camera lower light/fixed
camera coaxial light, click the associated
button to open each calibration screen.
HLGB-10302-01
Fixed Camera Light Calibration
Press the [START] button on the operation panel.
HLGB-10302-01
Fixed Camera Light Calibration
Remove the fixed camera light
calibration jig and click the OK
button.
When subsequently performing calibrations of
fixed camera middle light/fixed camera lower
light/fixed camera coaxial light, it is
unnecessary to remove the jig.