HLGB-10306-01 Auto Calibration (Recognition of Relationship for the Mu ltiple Recognition) If the recogn ition of relationship between PWB coord inate and mechanism coordinate has been perf ormed in adv a nce of this pro…

HLGB-10306-01
Auto Calibration (Recognition of
Relationship for the Multiple Recognition)
Click the Recognition of relationship
for the Multiple Recognition button on
the Multi-functional machine
calibration screen.
Click the Start button of Sequence 1.
Press the [START] button to start the
auto calibration.
If an error occurs and the process aborts, clean
the jig chips and then restart the calibration
from Sequence 1.

HLGB-10306-01
Auto Calibration (Recognition of
Relationship for the Multiple Recognition)
If the recognition of relationship between PWB coordinate and mechanism coordinate has
been performed in advance of this procedure, return the software limit for Y-axis to the
original value.
Remove the jig chips, calibration plate, and the jig nozzles.

HLGB-10307-01
Nozzle Changer Teaching
[Necessary jigs]
• Jig nozzle for nozzle changer
[Procedure]
Do not install a nozzle to the nozzle cartridge.