HLGB-10402-01 Matching of Y Axis Z-Ph as e Adjust the Z-phase setup position by adjusting the positional relation between the motor and ball screw . Move the rear head to th e center of Y axis to secure workin g space to…

HLGB-10402-01
Matching of Y Axis Z-Phase
Manually move the Y axis backward to
the position where the dog leaves the
ORG sensor.
Manually move the Y axis forward
little by little and stop at the boundary
position where the ORG sensor LED in
extinguished condition lights up.
Measure the distance from the LM
guide rail end to the LM guide face
with a scale.
By 2 times of measurements, the amount of movements from the dog detection position of an ORG sensor
to the present Z-phase position can be found.
Suppose that the present amount of movement is C.
Example : A (27 mm) - B (46.5 mm) = C (-19.5 mm)

HLGB-10402-01
Matching of Y Axis Z-Phase
Adjust the Z-phase setup position by adjusting the positional relation between the motor and ball screw.
Move the rear head to the center of Y
axis to secure working space to loosen
the coupling screws.
Loosen the M5 screw located on the
ball screw side of the coupling for the
front Y axis.
One of workers should hold the coupling for the front Y axis located on the unit rear side so
as to prevent the coupling from moving.
The other worker should adjust the Y axis so that a distance between the LM guide rail end
on the unit front side and the LM guide face becomes the target dimension (61mm) derived
by the procedure 7.
If the difference between the present amount of movements and the amount of Z-phase setup movement is
positive, move the Y axis to the CCW sensor side (front direction), and if the difference is negative, move it
to the CW sensor (rear direction).
Fasten the screw M5 on the ball screw side of the coupling with a torque driver.
Tightening torque :7.0 N・m
Measure the distance from the LM guide rail end to the LM guide face with a scale.
Suppose that this measured value is A.
Measure the dog detection position of the ORG sensor with a scale. Suppose that the
measured value is B.

HLGB-10403-01
H Axis Gear Z-phase Matching
Perform this working on both heads on the front side and rear side.
[Necessary jigs]
• Thickness gauge (t=1.0 mm)
[Procedure]
Rotate pinion for easy access of alain key.