HLGB-10403-01 H A xis Gear Z-phase Matching Close the explorer windo w . Press the power off switch. Press the power on switch. Click in an order of M/C SETUP menu ORG OFFSET tab R.H button. Click the Ab s. M ove but…

HLGB-10403-01
H Axis Gear Z-phase Matching
For the front side, open Properties
window for ac_control_param.ini file
in C:¥asm¥mcdata1.
For the rear side, open Properties
window for ac_control_param.ini file
in C:¥asm¥mcdata2.
“ ”
Uncheck “Read-only” on the Properties
window of the ac_param.ini file.
Click the OK button.
Open the ac_control_param.ini file by
Notepad.
Change the value of
PN100-PN101-PN102 of [AC_H].
Save the ac_control_param.ini file and
end.
Open the Properties window of the
ac_control_param.ini file and check
the “Read-only”.

HLGB-10403-01
H Axis Gear Z-phase Matching
Close the explorer window.
Press the power off switch.
Press the power on switch.
Click in an order of M/C SETUP menu
ORG OFFSET tab R.H button.
Click the Abs. Move button for move
mode and put checkmark on H axis.
Press the [ORG] button on the
operation panel.
Unless the gear is free against the motor shaft
of the H axis, the dog obstructs the CCW sensor
and the servo is turned off.
Check that the gear is completely free against
the motor shaft of the H axis.

HLGB-10403-01
H Axis Gear Z-phase Matching
Click in an order of ORG OFFSET tab
R.H button.
Click the Abs. Move button in the
move mode.
Click the check box for H axis and put
check in it to input “-1.1”.
Press the [START] button on the
operation panel.
Tighten the split fastening screw for
the H axis motor gear.
Click in an order of the ORG OFFSET
tab Change Offset button.