MAN00000772_SI-G200BB_SVCPDFA.pdf - 第316页

HLGB-1041 1- 01 Adjustment of Plunger Upper/Lower Backward Detect Sensor Perform this working on b o th he ads on t he front side and rear side. [Necessary jigs] • Thickness gauge [Procedure] Press in the mechani cal val…

100%1 / 712
HLGB-10410-01
Gap Adjustment for Head Unit
Mechanical Valve and Plunger
[Gap adjusting procedure]
Loosen the cap screws (4 pcs, C3 x 5).
Adjust the gap between the end of the
retracted plunger and the end of the
projected mechanical valve to 1.5 mm
using a thickness gauge.
The mechanical valve and the plunger head
should be parallel to each other.
While matching the axis center in
height direction, fasten the cap screws
(4 pcs, C3 x 5) to fix the plunger.
HLGB-10411-01
Adjustment of Plunger Upper/Lower
Backward Detect Sensor
Perform this working on both heads on the front side and rear side.
[Necessary jigs]
Thickness gauge
[Procedure]
Press in the mechanical valve.
Pull out the plunger by hand, and
pinch a thickness gauge of t=1.0 mm
between the plunger and mechanical
valve.
Move the bracket to adjust the sensor
position so that the LED for the
plunger return sensor extinguishes in
this state.
HLGB-10411-01
Adjustment of Plunger Upper/Lower
Backward Detect Sensor
Press in the mechanical valve.
Pull out the plunger by hand, and pinch a thickness gauge of t=1.2 mm between the
plunger and the mechanical valve.
Check that the LED for the plunger return sensor lights up in this state.
Thickness of thickness gauge State of LED for plunger return
sensor
1.0 mm Extinguish
1.2 mm Lights-up
Non (Origin position) Lights-up