MAN00000772_SI-G200BB_SVCPDFA.pdf - 第328页
HLGB-10414-01 Phase A djustment for Nozzle Click the RT button on the Axis MOTION screen. Click the Jog Move button. Press the left and right cursor key to move the turret No.1 to the front. T urn the notch on the spring…

HLGB-10414-01
Phase Adjustment for Nozzle
Click in an order of MANUAL menu
AXIS MOTION tab XY button.
Click the Jog Move button in the move
mode.
Press the right cursor to jog-move the
head to vicinity of No.120 of head
supply part.
Click the Return button to close the
XY Axis screen.
Loosen CP-3x10 to remove the
mechanical valves for Index 1 and
Index 2.

HLGB-10414-01
Phase Adjustment for Nozzle
Click the RT button on the Axis
MOTION screen.
Click the Jog Move button.
Press the left and right cursor key to
move the turret No.1 to the front.
Turn the notch on the spring holder to
deep side.
Pull the spring holder toward you with
the spring being lowered down to
remove the spring holder.
Be careful to prevent the inner shaft from
falling.
Remove the spring.
Pull out the inner shaft from lower
side of the head.

HLGB-10414-01
Phase Adjustment for Nozzle
Do not remove the set screw fixing the small
gear. Otherwise, the set shoe may fall.
Turn the emergency stop switch to
release emergency stop.
Click the [ORG] button to return the
system to the original position.
Click in an order of MANUAL menu
AXIS MOTION tab.
Check that current position of the RN
axis is 0 .