Anleitung X2 SP 1 und 3.pdf - 第24页
2 Assembly instructions Special design for manual tray on X2 at loca tion 1 or 3 Special Design 04/2007 Edition 24

Special Design 2 Assembly instructions Special design for manual tray on X2 at location 1 or 3
04/2007 Edition
23
2.8 Software settings in SITEST
: Deactivate all the removed nozzle changers in SITEST.
2.9 Programming under SIPLACE Pro
2
For programming under SIPLACE Pro, use the instructions
"Programming guide for arbitrary carrier under SIPLACE Pro" (item no.: 00194607-xx) 2
2
2.10 Possible causes of error
Pick-up problems 2
– The trays were not fixed using the magnets provided.
Solution: Fix the trays again.
– The trays are not described correctly in SIPLACE Pro.
Solution: Correct the tray description.
– Placement head picks up at the wrong place.
Solution: Determine offset values using the Arbitrary Carrier instructions and enter correct val-
ues.
– The trays have no or the wrong offset values.
Solution: Determine the right offset values (see instructions).
– Tray holder was not fitted correctly.
Solution: Tighten all the screws.
– The trays are not fixed without stress using the magnets provided.
Solution: Fix the trays again.
2
2
2
2
2 Assembly instructions Special design for manual tray on X2 at location 1 or 3 Special Design
04/2007 Edition
24