System components and configurations
System configuration Setup Center GUI
14 Installation Manual SIPLACE Setup Center 2.3
from the stock and need to adjust the quantity if necessary.
This scenario offers a higher amount of operation safety, because the SIPLACE Setup Center and
a local MSDE database are installed to different computers for each production line. If one
component of SIPLACE Setup Center encounters an error, only one production line is affected.
Central database
The SIPLACE Setup Center database can be installed to any available Microsoft SQL Server 2000
(SP3a). In this case, the customer is responsible to set up a backup & recovery strategy and must
provide an operating Microsoft SQL Server 2000 (SP3a).
Database Version
The database is upgraded by the installation. In this step, the current verification data is deleted and
the setup must be verified again after the installation. All data that is connected to unique IDs (Unique
IDs for packaging units and change over tables) will be kept in the database. This means that after
re-verifying the fill-levels of the packaging units are restored.
Database Backup & Recovery Strategy
The setup automatically creates two database jobs, which backup the SIPLACE Setup Center database.
The first job Full backup executes a backup of the database and several maintenance tasks. The job
starts every week Sunday at 00.00. The second job Delta backup executes only a backup of the
database and starts every day, except Sunday at 00:00. During the backup SIPLACE Setup Center
database is locked and the Setup Center GUI have to wait until unlock.
The backups are stored in
C:\Programme\Siemens SIPLACE\SIPLACE Setup Center\Database
.
A job completion event is written to the Windows application log. More details are written to the file
SiplaceSetupCenterReport.txt
in the database directory.
4.2.3 Setup Center GUI
It is recommended to install SIPLACE Setup Center GUI once for each line and pre-setup area. With the
"central database" scenario these can use the same database at the same time.
It is recommended to use two barcode scanners per line and SIPLACE Setup Center GUI installation.
4.2.4 Forced Setup Verification
Activate the forced setup verification at the placement station if it is necessary.
4.2.5 Docking Stations
The installation of the docking station is necessary, if equipment of the X-Series is used and a pre setup
area or kitting area exists.
NOTE:
The database version for SIPLACE Setup Center 2.3 is 1.0.1.7.
The database version for SIPLACE Setup Center 2.2 SP1 is 1.0.1.6.
The database version for SIPLACE Setup Center 2.2 is 1.0.1.5.
NOTE:
When working with identical component lots (without Unique IDs), the fill-levels of the packaging
units must be restored manually after the installation (fill-level corrections).
System components and configurations
Recommended Installation Scenarios System configuration
Installation Manual SIPLACE Setup Center 2.3
15
4.2.6 Recommended Installation Scenarios
4.2.6.1 Local Database
4-2: System configuration Local Database
Usually the system configuration "Local Database" is for a small manufacturing facility with one ore two
production lines. An assumption for the configuration is that the SIPLACE Pro database is also installed
locally and no SIPLACE EDM is used. The Setup Center GUI is directly connected to the local SIPLACE
Pro and local Setup Center Database and manages the setup verification for the stations connected via
the SIPLACE LAN.
This scenario can also be used, if a step-by-step introduction is helpful. Then it may also helpful to omit
the "Forced Setup Verification" activation and to start with the unforced setup verification. After a definite
time the forced setup verification can be activated at station and Setup Center.
System components and configurations
System configuration Recommended Installation Scenarios
16 Installation Manual SIPLACE Setup Center 2.3
4.2.6.2 Central Database
4-3: System configuration Central Database
Usually the system configuration "Central Database" is for manufacturing facility with more than one
production line. Prerequisites for the configuration is
the SIPLACE Pro database is also installed centrally, or
the SIPALCE EDM product is deployed, or
a pre setup area with Setup Center is planned, or
packaging units often moves between different placement lines.
The Setup Center GUIs are connected to the local SIPLACE Pro and to the central Setup Center
Database. The docking stations are connected via CAN-Bus to the SC Computer. The pre setup unit is
the reason, why a central Setup Center Database is necessary.