00195397-01_Installation Manual Setup Center 2.3 - 第41页
Installation Optional: Docking Station Hardware Installation Installation Manual SIPLACE Setup Center 2.3 41 Connection Example 2 5-14: Connection exampl e 2: CAN bus cable NOTE: The integrated termina l resistor can be …

Installation
Hardware Installation Optional: Docking Station
40 Installation Manual SIPLACE Setup Center 2.3
See the connection scenarios below for CAN Bus cable connection.
CAN Bus Cable Connection Examples
Connection Example 1
5-13: Connection example 1: CAN bus cable
Legend:
1. CAN Bus Address Switch
2. CAN Connection
NOTE:
The integrated terminal resistor can be connected and simultaneously connects / disconnects
the outgoing bus cable when deactivating / activating. This allows an easy start up of the bus
system one segment at a time.

Installation
Optional: Docking Station Hardware Installation
Installation Manual SIPLACE Setup Center 2.3
41
Connection Example 2
5-14: Connection example 2: CAN bus cable
NOTE:
The integrated terminal resistor can be connected and simultaneously connects / disconnects
the outgoing bus cable when deactivating / activating. This allows an easy start up of the bus
system one segment at a time.

Installation
Hardware Installation Optional: Docking Station
42 Installation Manual SIPLACE Setup Center 2.3
Connection Example 1 and 2
5-15: Connection example 1 and 2: CAN bus cable
Compressed Air and Power Supplies
X Connect to the compressed air supply.
X Set the pressure reducer on the pneumatic connection (external) to 5.5 bar.
X Switch off the power supply and connect the CAN Bus cable to the device.
NOTE:
The terminating resistors are activated via the slide switch (XXXXXX) at the starting and final
point of the bus system. At the same time the connection points (2C+ / 2C-) for the outgoing bus
cable are switched off.
At all other nodes of the bus system the corresponding terminating resistor must be activated!
NOTE:
The compressed air and power connections can be found on the back of the docking station.
DANGER:
Never cover the air discharge opening in the integrated fan and the ventilation slits on the side
of the device!
Covering these could lead to overheating and destruction of the power pack.