ysm20r_cabpara - 第20页
26 1 1. Specications YSM20R (SESMK18400-00) v2.001 Air suppl y source 0.45 M Pa or more (4. 5 kgf / cm 2 or more), clean and dry air * T o maintain a sufficient air flow rat e, prepare a supply air hose with an inside d…

25
11. Specications
YSM20R (SESMK18400-00) v2.001
11. Specifications
11.1 Major specifications
Machine
type and
model
Type PV :
YSM20R-2 model : KMK-000
YSM20R-1 model : KMK-100
Type SV :
YSM20R (SV)-2 model : KMK-500
YSM20R (SV)-1 model : KMK-600
Outside
dimensions
L 1,374 x W1,857 x H1,445 mm (Main unit only)
Weight
Approx. 2,050kg (Main unit only / 2 beams, Dual-stage specifications)
Approx. 1,950kg (Main unit only / 1 beams, Single-Lane specifications)
Approx. 70kg (32-feeder exchange carriage)
Approx. 160kg (cATS10)
Approx. 250kg (sATS30)
Approx. 290kg (sATS30NS)
Noise to be
generated
78dB (A) or less
* The dimensions exclude any removable projecting parts.
* For detailed dimensions or dimensions with various options installed, see the figure below.
* The following figure shows the machine with various options installed, such as feeder exchange carriage.
1270
(The space necessary
to move cATS10.)
1057
(During sATS30NS
operation)
1857
864
4184
2975 345
228
900
(Hight of Trandport)
400
450
1541
60 140
1744(Both Side External CONV.)
1559(R Side External CONV.)
1559(L Side External CONV.)
1372(Standard CONV.)
EL POWER SUPPLYAIR SUPPLY
EL POWER SUPPLY
EL POWER SUPPLY
AIR SUPPLY
AIR SUPPLY
1850
1445
1621
1340(Monitor)
1045(Keyboard)
927
1347
1797
30 1797 30
1857187
124 1125
686
343
436 742
2975
225
25
435
200
658(SL,DS)
413
CONVEYOR
(SL,DS)

26
11. Specications
YSM20R (SESMK18400-00) v2.001
Air supply
source
0.45 MPa or more (4.5 kgf / cm
2
or more), clean and dry air
* To maintain a sufficient air flow rate, prepare a supply air hose with an inside diameter of 8mm or more.
* Supply the air with excellent quality that has passed through the air dryer and air filter on the line side
of the air supply source. (The air filter built-into this machine is intended to protect the machine.
To maintain the function and performance of this machine at their optimal levels for an extended period
of time, the air must be kept clean and dry on the line side of the customer’s air supply source.)
* Set pressure to 0.40 MPa (0.39MPa
to
0.41MPa).
Air
consumption
flow rate
Average consumption Max consumption
YSM20R-2 2Head
High-speed multi-
purpose (HM) head x 2
240 ℓ / min [ANR] 340 ℓ / min [ANR]
YSM20R-2 2Head
Odd-shaped
components (FM) head x 2
140 ℓ / min [ANR] 320 ℓ / min [ANR]
YSM20R-1 1Head
High-speed multi-
purpose (HM) head x 1
130 ℓ / min [ANR] 290 ℓ / min [ANR]
YSM20R-1 1Head
Odd-shaped
components (FM) head x 1
80 ℓ / min [ANR] 280 ℓ / min [ANR]
* When the machine is equipped with the ATS carriage, it is necessary to add approx. 10 liters / min.
(ANR) to the air consumption flow rate shown above.
* "ANR" is an abbreviation of "Atmosphere Normal de Reference" and shows the standard reference
atmospheric status (temperature is 20°C, relative humidity is 65%, and absolute pressure is 101.3 kPa
(1.03 kgf / cm
2
or 760mmHg)).
Power
supply
Power requirement : 3-phase AC power, 200 / 208 / 220 / 240 / 380 / 400 / 416 V ± 10%
Frequency : 50Hz / 60Hz
Power capacity : 10.4kVA
Average power consumption : 1.9kW (under standard operating conditions)
Power cable
terminal
size
b c
a
Terminal Part No. KLW-M643A-00X
Manufacturers TOYOGIKEN CO.,LTD
Manufacturers Part No. FPS-80
Bolt diameter M5
Max. Terminal width (a) 12.2 mm
Max. Terminal length(b) 6.5 mm
Min. Terminal length(c) 7 mm
Tightening torque 2.0-3.0N
・
m
Power
supply
connection
Power cable conductor cross-section area : 6mm
2
or more.
L1
L2
L3
PE
Ring-tongue crimp terminal
Insulated crimp terminal
* To prevent electric shock accidents, make sure that the power source is shut down securely
before connecting the power cable.
* Connect the main body grounding cable securely.
* L1, L2, and L3 show the 3-phase AC power cables and PE shows the grounding cable.

27
11. Specications
YSM20R (SESMK18400-00) v2.001
Environmental
conditions
Temperature Function assurance : 15 to 35°C
Accuracy assurance : 20 to 28°C
Humidity Allowable range : 20 to 80% (No condensation)
Optimal range : 50 to 60%
* Keep a humidity of approx. 40% or more as static electricity prevention measures.
* When using an industrial humidifier, use water equivalent to DI water.
Transient voltage
category
category III
Pollution degree
degree 2
Atmosphere There shall be no dirt and dust.
There shall be no organic solvent vapor, sulfurous acid gas, chlorine gas, and flammable
gas.
Altitude 1,000 m or less above sea level
* This avoids that the air pressure or cosmic ray adversely affects the insulation
performance.
Installation floor
conditions
The floor withstanding load capacity shall be approx. 850kg / m
2
.
* For the floor withstanding load capacity, consult the specialists who know the installation
place well with the information on equipment weight, floor sharing area, and adjuster foot
positions.
* The floor shall be flat and have sufficient strength so that it does not vibrate during
operation. The floor shall have the concrete strength or its equivalent.
In particular, wooden floor, office floor, and grating are not allowed to use.
* If the floor is not concrete, consult the specialists who know the installation place well and
construct the reinforcement work for the portions where the equipment adjuster feet are
placed.
* When the feeder exchange carriage is shared by different machine models, a flatness of
10mm or less is required for the floor installation areas of all target equipment.
Ambient noise There shall be no significant noise.
Equipment warning beep should be heard without fail.
Ambient light Strong light such as sunlight does not enter the vision system
(optical image processing system).
Noise immunity See "10.7 CE marking".
Noise emission See "10.7 CE marking".
Board
transport
height
900mm ± 10mm (From the floor surface to the upper surface of the conveyor belt)
Input data Number of
mounting points
12,800 points (Note that the number of mounting points decreases depending on the
number of boards, the number of blocks, or the number of fiducial marks.)
Component
types
255 types / board
Board data 100 MB / unit
Number of
fiducial marks
128 sets / board
Data entry
method
Data entry unit supplied with the machine main unit
Positioning
resolution
X-axis / Y-axis /
Z-axis
0.001mm
R-axis 0.001°
External
interface
LAN*, 1 port (See "7.5 Network" and "7.6 Anti-virus measures".)
Internal
memory
Built-in 4GB flash card *, 1 pc.
* For storage of files, such as OS, mounter application software, board data, component data,
vision data, machine information, and production history information, etc.
External
memory
USB flash memory with a capacity of 8GB or more *, 1 pc.
(Supplied as standard accessory : For data backup)