User’s Manual Test Program S ITEST Software Version 10.xx Edition 03/98 1 - II

User’s Manual Test Program SITEST
Software Version 10.xx Edition 03/98
1 - I
Contents
Page
General Functions
1.1 Head Reference Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 - 1
1.2 Gantry Reference Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 - 2
1.3 Saving MA-Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 2
1.4 Head. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 3
1.5 I/O Ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 4
1.6 "Miscellaneous" Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 - 8
1.6.1 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 9
1.6.2 Run Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 10
1.6.3 Machine Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 10
1.7 Teach Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 14

User’s Manual Test Program SITEST
Software Version 10.xx Edition 03/98
1 - II

User’s Manual Test Program SITEST 1 General Functions
Software Version 10.xx Edition 03/98 1.1 Head Reference Run
1 - 1
1 General Functions
1.1 Head Reference Run
Prior to starting to work with the test program it is required that the axes approach their reference positions.
On SIPLACE 80S machines, the reference run must be performed for both gantries. To this end, the respec-
tive gantry must first be activated using the "Select gantry" option on the main menu (see section 0.4.2).
NOTE
Prior to performing the gantry reference run, the head reference run of the revolver head must first be
carried out. On SIPLACE 80F machine types, the head reference run must be performed for the IC-head as well.
●
From the main menu select the Head reference run option and press the RETURN key.
The "Head reference run" menu is displayed on the screen.
Overview of the Functions:
-
RV-Head ref. run Reference run of the revolver head
-
Close nozzles Close nozzles
-
IC-head refer. run Reference run of the IC-head
●
Select the RV-Head ref. run or IC-head refer. run function and press the RETURN key and the START
button. The selected head of the active gantry performs a reference run.
●
If you only wish to close the nozzles and move the segments to the 0-degree position, select the Close
nozzles function and press the RETURN key and the START button.
All nozzles on the head of the active gantry are then closed and moved to the 0-degree position.
NOTE
The "Close nozzles" function can only be performed with the vacuum supply turned on.
●
Press the ESC key, to return to the SITEST main menu.
Head reference run
RV-Head ref. run
Close nozzles
IC-head refer. run
is only displayed at
type SIPLACE 80F