2 Functions for the A djustment of the Machine User’s Manual Test Program S ITEST 2.3 Functions Software Version 10.xx Edition 03/98 2 - 8 2.3 Functio ns Using the op tions o f the "Func tions" me nu it is poss…

User’s Manual Test Program SITEST 2 Functions for the Adjustment of the Machine
Software Version 10.xx Edition 03/98 2.2 Functions of the Motor Control Board
2 - 7
Overview of the Functions:
-
Step star axis cycling the revolver head so that it advances by one segment
-
Screwdriver 1 to open/close the sealing piston in the segment of the pick-up station
-
Screwdriver 2 to open/close the sealing piston in the segment of the rejecting station
-
Actuate dp 1 to swivel dp1-drive toward segment
-
Actuate dp 2 to swivel dp2-drive toward segment
-
Centering no measur. to close jaws of centering station without CRDL-testing procedure
-
Centering with meas. this function is not used in this software version
-
Air blow placement to switch the "blow air" supply at the pick-up station on/off
(serves to adjust the "blow air" in the placement circuit)
-
Air blow reject to switch the "blow air" supply at the reject station on/off
(serves to adjust the "blow air" in the rejecting circuit)
-
Continuous run to perform the continuous run using one of the functions of the motor control board
-
Placement circuit Menu for testing the head functions in the placement circuit
●
In order to cycle the revolver head so that it advances by one segment, select the
Step star axis
function
and press the RETURN key.
●
If you wish to execute a single function, select the desired function and press the RETURN key.
The selected function is executed.
●
If you wish to carry out a continuous run by using one of the functions of the motor control board, select the
menu option
Continuous run
and press the RETURN key.
The "Continuous run" is now displayed on the screen.
●
Select the desired function and press the RETURN key. The continuous run is executed for the selected
function until it is terminated by pressing the ESC key.
●
Press the ESC key twice to return to the SITEST main menu.
Step star axis
Screwdriver 1
Screwdriver 2
Actuate dp 1
Actuate dp 2
Centering no measur.
Centering with meas.
Air blow placement
Actuate air blow rej
Continuous run
Motor control board
Continuous run
C.r screwdriver 1
C.r screwdriver 2
C.r swivel-in dp1
C.r swivel-in dp2
C.r center no mesur
C.r center with meas
C.r air blow placement
C.r air blow reject

2 Functions for the Adjustment of the Machine User’s Manual Test Program SITEST
2.3 Functions Software Version 10.xx Edition 03/98
2 - 8
2.3 Functions
Using the options of the "Functions" menu it is possible, among others, to test conveyor and component table
functions and to determine the x and y-coordinates for every compartment of the nozzle changer. In the
following, only those functions are described that are used for adjusting or testing the machine. Calibration of
the nozzle changer and the coplanarity laser module are described in chapter 4 "Calibration Functions" of this
manual.
●
Select the Functions option from the main menu and press the RETURN key.
The " Functions" menu is displayed on the screen.
Overview of the Functions:
-
Conveyor Menu for checking the conveyor functions
-
CRDL Menu for checking the CRDL test functions
-
Component-table Menu for checking the component table functions
-
Nozzle changer Menu for calibrating the RV and IC nozzle changers
-
Coplanarity function Menu for calibrating the coplanarity laser module
-
Width adjustment Menu for adjusting the width adjustment
-
Movable conv. side Calibration of the conveyor width for automatic width adjustment
NOTE
If gantry 2 of a SIPLACE 80S is active (MC-AKTIV: 2), only the "Component table" and "Nozzle changer"
menu items can be selected. If SIPLACE 80 F is active, only "Component table 3" can be selected, "Compo-
nent table 1", the V24 cable is to be plugged into a different socket beforehand.
Functions
Conveyor
Component-table
Nozzle changer
Coplanarity function
Movable conv. side
Width adjustment
only available at
type SIPLACE 80F
CRDL tester

User’s Manual Test Program SITEST 2 Functions for the Adjustment of the Machine
Software Version 10.xx Edition 03/98 2.3 Functions
2 - 9
2.3.1 Conveyor
●
Select the
Conveyor
option from the "Functions" menu and press the RETURN key. The "Conveyor" menu
is displayed on the screen.
Overview of the Functions:
-
PCB in to stopper to transport the PCB from the input to the center conveyor
-
PCB out to transport the PCB from the center to the output conveyor
-
Pass PCB to convey the PCB through the station
-
PCB clamping to open close the transport clamping system
If the clamping system was closed it will now be opened. If the clamping system
was open it will now be closed.
-
PCB Stopper to extend/retract the PCB stopper
-
PCB conveyor motors all conveyor belts running at fast belt speed.
-
PCB cen.& out. conv. center and output conveyors running at slow conveyor speed.
-
Reset PCB transport to move stopper to neutral position
-
Stop PCB conveyor to stop conveyor motors (required for the adjustment of conveyor speed)
-
PCB to input convey. to convey the PCB to the input conveyor
●
Select the desired function from the "Conveyor" menu and press the RETURN key.
The function is now executed.
●
Press the ESC key, to return to the "Functions" menu.
Functions
Conveyor
CRDL tester
Component-table
Nozzle changer
Coplanarity function
Width adjustment
Movable conv. side
PCB in to stopper
PCB out
Pass PCB
PCB clamping
PCB Stopper
PCB conveyor motors
PCB cen.& out. conv.
Reset PCB transport
Stop PCB conveyor
PCB to input convey.
Conveyor