00191174-01.pdf - 第41页
User’s Manual Test Program SITEST 2 Functions for t he Adjustment of the Machine Software Version 10.xx Edition 03/98 2.3 Functions 2 - 13 2.3.4 Width Adjustment NOTE The func tions of the "W idth a djustm ent"…

2 Functions for the Adjustment of the Machine User’s Manual Test Program SITEST
2.3 Functions Software Version 10.xx Edition 03/98
2 - 12
●
From the "Single functions" menu select the
Track
option and press the RETURN key. The "Track" input
field is opened.
●
If you wish to test, for example, a specific linear feeder, enter the number of the track on which the feeder is
set up and confirm your entry by pressing the RETURN key
.
●
Close the input field by pressing the ESC key.
●
Select the function to be tested for the component that is set up on the track entered or that can be
activated via the address of this track (e.g. "Actuate lin. feeder" for the linear feeder that is set up on the
track entered) and press the RETURN key
.
The function will now be executed once.
●
To test a single function in the continuous run mode, select the
Continuous run
option from the
"Component-table" menu and press the RETURN key.
The "Continuous run" menu is displayed on the screen.
NOTE
To test the functions "Linear feeder" and "Output" in the continuous running mode, it is necessary - prior
to
selecting the continuous run function - to first enter the number of the desired track, by selecting the "Track"
menu option from the "Single functions" menu (see above) and to confirm the entry by pressing the RETURN
key, and subsequently to actuate the ESC key twice to exit from the "Single functions" menu.
Overview of the Functions:
-
Tape cutting unit to activate the tape cutting unit
-
Open linear feeder testing function
-
Actuate lin. feeder to activate the linear feeder
-
Output to activate the tape feeder
●
Select the function to be tested for the component that is set up on the track entered or that can be activa-
ted via the address of this track and press the RETURN key
.
The function continues to be executed until the continuous run is terminated by pressing the ESC key.
●
Press the ESC key twice to return to the "Functions" menu.
Functions
Conveyor
CRDL
Component-table
Nozzle changer
Coplanarity function
Width adjustment
Movable conv. side
Flux function
Coplanarity function
Single functions
Continuous run
Display version
Waiting time
Component-table
Continuous run
Tape cutting unit
Open linear feeder
Actuate lin. feeder
Output

User’s Manual Test Program SITEST 2 Functions for the Adjustment of the Machine
Software Version 10.xx Edition 03/98 2.3 Functions
2 - 13
2.3.4 Width Adjustment
NOTE
The functions of the "Width adjustment" menu are only available if gantry 1 is "active".
●
From the "Functions" menu select the
Width adjustment
option and press the RETURN key. The "Width
adjustment" menu is displayed on the screen.
NOTE
During the performance of all functions of the width adjustment system, the elevating table must be in the
lowered
position.
Overview of the Functions:
-
Decrease width slow to adjust the conveyor width in small increments
-
Increase width slow to adjust the conveyor width in small increments
-
Decrease width fast to adjust the conveyor width in large increments
-
Increase width fast to adjust the conveyor width in large increments
-
Calibrate width adj. Determination of the reference conveyor width using a PCB that is exactly
100 mm in width (required for automatic width adjustment).
●
From the "Width adjustment" menu select the desired function, and press the RETURN key.
The function is now executed on the current conveyor.
NOTE
The value of the gantry position determined can be saved using the main menu option
File Manager
-->
Store MA-file
(see section 1.3).
●
Press the ESC key to return to the "Functions" menu.
Functions
Conveyor
CRDL
Component-table
Nozzle changer
Coplanarity function
Movable conv. side
Width adjustment
Decrease width slow
Increase width slow
Decrease width fast
Increase width fast
Calibrate width adj.
Width adjustment

2 Functions for the Adjustment of the Machine User’s Manual Test Program SITEST
2.4 Vacuum Board Software Version 10.xx Edition 03/98
2 - 14
2.3.5 Determination of the Position of the Movable Conveyor Side
To determine the current conveyor width, the position of the movable conveyor side is to be approached.
NOTE
The execution of the "Movable conv. side" function is only possible with gantry 1.
●
Adjust the conveyor width to that of the 100 mm wide PCB.
●
From the "Functions" menu select the
Movable conv. side
function and press the RETURN key.
The position of the movable conveyor side is determined and the result is displayed in the lower left corner
of the screen, and will be stored in the "MA-DATE-file.
●
Press the ESC key twice to return to the SITEST main menu.
2.4 Vacuum Board
The functions of this menu permit all required vacuum checks to be performed.
●
From the main menu select the "Vacuum" option and press the RETURN key
.
The "Vacuum" menu is displayed on the screen.
Overview of the Functions:
-
Measure vac.placement to measure the vacuum in the pick-up circuit and display the value
-
Measure vac. reject to measure the vacuum in the rejecting circuit and display the value
-
Turn screwdriver 1 one-time actuation of the screwdriver in the pick-up station
(no display).
-
Turn screwdriver 2 one-time actuation of the screwdriver in the rejecting station
(no display).
-
Step star axis to cycle the revolver head by one segment
-
Measure all vacuum to measure all vacuum values (pick-up and reject circuits) for all segments
-
Show vacuum results to display the measured vacuum values
Vacuum
Measure vac.placement
Measure vac. reject
Turn screwdriver 1
Turn screwdriver 2
Step star axis
Measure all vacuum
Show vacuum results
Print vacuum results
Alternate IC-vacuum
Alternate IC air-blow
Measure IC vacuum