00191174-01.pdf - 第46页

2 Functions for the A djustment of the Machine User’s Manual Test Program S ITEST 2.5 Continuous Run Software Version 10.xx Edition 03/98 2 - 18 ● Make the desired chang es and pr ess the RETURN ke y to ac cept the chang…

100%1 / 88
User’s Manual Test Program SITEST 2 Functions for the Adjustment of the Machine
Software Version 10.xx Edition 03/98 2.5 Continuous Run
2 - 17
Press the ESC key to exit from the "Ct.run RV-head" menu.
If you wish to have the RV-head perform an endurance run. select the
Ct.r. FORCE RV-head
menu
option from the "Continuous run" menu and press the RETURN key
.
The "Ct.r. FORCE RV-head" menu is displayed on the screen.
Overview of the Functions:
-
Start cont.run FORCE to start the continuous run
-
Change parameter to open the menu for changing the run parameters for the endurance run
If you wish to change the force setting at which the continuous run is to be carried out, select the
Change
parameter
menu option and press the RETURN key.
The input menu is opened.
Change the force setting to the desired value and press the RETURN key to accept the change.
Press the ESC key to exit from the input menu.
To start the endurance run select the
Start cont.run FORCE
function and press the RETURN key.
The continuous run continues to be carried out until you terminate it by pressing the ESC key.
Press the ESC key to return to the "Continuous run" menu.
To perform a continous run of the IC-head, select the
Cont.run IC-head
menu option from the "Continuous
run" menu and press the RETURN key.
The "Cont.run IC-head" menu is displayed on the screen.
Overview of the Functions:
-
Start cont. run head to start the continuous run
-
Change parameter to open the menu for changing the run parameters for the head continuous run
-
Display result the results of the continuous head run are read back by the machine controller
and displayed on the screen.
If you wish to change the parameters for the execution of the continuous head run, select the
Change
parameter
menu and press the RETURN key.
The input menu is opened.
Continuous run
Ct.run revolver head
Cont.run IC-head
Ct.r. FORCE rev.head
Ct.run FORCE IC-head
Start cont.run FORCE
Change parameter
Ct.r. FORCE RV-head
Continuous run
Ct.run revolver head
Cont.run IC-head
Ct.r. FORCE rev.head
Ct.run FORCE IC-head
Start cont. run head
Change parameter
Display result
Cont.run IC-head
2 Functions for the Adjustment of the Machine User’s Manual Test Program SITEST
2.5 Continuous Run Software Version 10.xx Edition 03/98
2 - 18
Make the desired changes and press the RETURN key to accept the changes.
Press the ESC key to exit from the input menu.
To start the continuous head run, select the
Start cont. run head
function and press the RETURN key.
The continuous run continues to be performed until you stop it by pressing the ESC key.
If you wish to execute another function of the "Cont.run IC-head" menu, select the desired function from
the menu and press the RETURN key
.
The selected function is executed.
Press the ESC key to exit from the "Cont.run IC-head" menu.
If you wish to perform an endurance run of the IC-head, select the
Ct.r. FORCE IC-head
menu
option from the "Continuous run" menu and press the RETURN key
.
The "Ct.r. FORCE IC-head" menu is displayed on the screen.
NOTE
The menu functions of the "Ct.r. FORCE IC-head" menu and the procedures on this menu are identical
to those of the menu "Ct.r. FORCE RV-head".
Press the ESC key to return to the SITEST main menu.
User’s Manual Test Program SITEST
Software Version 10.xx Edition 03/98
3 - I
Contents
Page
Calibration Functions
3.1 Preparation for the Performance of the Calibration Functions . . . . . . . . . . . . . . . . . . . . 3 - 1
3.1.1 Verification and Acceptance of the Calibration Piece Position. . . . . . . . . . . . . . . . . . . . . . . .3 - 2
3.1.2 Teaching the Calibration Piece Position. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 - 3
3.2 Calibration of the Component Camera. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 4
3.2.1 Further Component Camera Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 - 5
3.2.1.1 Changing the Illumination Values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 - 5
3.3 Calibration of the PCB Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 - 6
3.3.1 Measuring the Offset Between PCB Camera and Component Camera. . . . . . . . . . . . . . . . . 3 - 7
3.4 Measuring Segment Offset I (Top Segment Offset) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 8
3.5 Calibration of the Machine Zero Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 9
3.6 Measuring the Pick-Up Positions of Tracks 1 and 120 . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 11
3.7 Measuring the Position of the PCB Reference Corner . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 12
3.8 Calibration of the IC-Camera (SIPLACE 80F). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 13
3.8.1 Changing the Illumination Values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 - 15
3.8.2 Measuring the Offset From IC-Head to Component Camera and IC-Camera Position . . . . 3 - 16
3.9 Calibration of the Flip-Chip Camera (SIPLACE 80F). . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 17
3.10 Calibration of the Coplanarity Laser Module (SIPLACE 80F). . . . . . . . . . . . . . . . . . . . . 3 - 19
3.11 Calibration of the Nozzle Changer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 20
3.11.1 Calibration of the RV-Nozzle Changer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 21
3.11.2 Calibration of the IC-Nozzle Changer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 24
3.12 Saving the Calibration Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 26