User’s Manual Test Program S ITEST 3 Calibration Functions Software Version 10.xx Edition 03/98 3.1 Preparation for t he Performance of the Calibration Functi ons 3 - 3 3.1.2 Teaching the Calibration Piece Position NOTE …

100%1 / 88
3 Calibration Functions User’s Manual Test Program SITEST
3.1 Preparation for the Performance of the Calibration Functions Software Version 10.xx Edition 03/98
3 - 2
3.1.1 Verification and Acceptance of the Calibration Piece Position
From the main menu select the
Vision system
option and press the RETURN key.
The "Vision system" menu (see section 3.5) opens.
Select the
Move to position
menu item and press the RETURN key.
Using the key combination ALT+8 switch the monitor to the PCB camera.
Check whether the calibration piece fiducial can be seen in the search window of the PCB camera.
Using the key combination ALT+9 switch the monitor back to the normal program mode.
NOTE
If the calibration piece fiducial cannot be seen in the search window of the PCB camera, the position of the
calibration piece must be taught (see section 3.1.2).
From the main menu select the
Vision system
option and press the RETURN key.
The "Vision system" menu is displayed on the screen.
Overview of the Functions:
-
Pos.calibration tool to approach the calibration piece position and to adopt the position determined
-
Adopt current pos. function to adopt the current PCB camera position
-
Teach position menu to teach or enter the calibration piece position
-
PCB camera Menu of the PCB camera functions
-
Component camera Menu of the component camera functions for the revolver head
-
IC-camera Menu of the IC camera functions
-
Flip-chip camera Menu of the Flip-Chip camera functions
To adopt the calibration piece position select the
Adopt current pos.
menu item and press the
RETURN key.
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 10.xx Edition 03/98 3.1 Preparation for the Performance of the Calibration Functions
3 - 3
3.1.2 Teaching the Calibration Piece Position
NOTE
The steps described in the following must only be performed if the fiducial of the calibration piece cannot be
found in the search window.
From the "Vision system" menu select the
Teach position
option and press the RETURN key.
The "Enter current pos." menu is now displayed on the screen.
Overview of the Functions:
-
Teach position to teach the calibration piece position using the cursor keys
↑↓ ← →
(i.e. teach onto the center of the fiducial on the calibration piece)
-
Enter position to edit the calibration piece position (fiducial center on the calibration piece)
Select the
Teach position
function and press the RETURN key.
The monitor switches to the PCB camera.
Teach the position of the calibration piece using the cursor keys
↑↓ ←
. The fiducial on the calibration
piece must be visible in the search window.
(For details on the procedure for traversing the gantry during teaching, see section 0.4.1).
Terminate the teaching operation by pressing the ESC key.
The monitor switches back to the normal program mode.
After the teaching process has been completed, the position values are displayed on the screen.
Press the ESC key three times to return to the SITEST main menu.
From the main menu select the
Gantry positions
option and press the RETURN key.
The "Gantry positions" menu is displayed on the screen (see section 3.5).
From the "Gantry positions" menu select the
Calibrate
option and press RETURN key. The "Calibrate"
menu is displayed on the screen.
Select the
Pos.calibration tool
function and press the RETURN key.
The calibration of the calibration piece position is performed.
Press the ESC key twice to return to the SITEST main menu.
Save the calibration piece position using the
File Manager
-->
Store MA-file
menu function (see
section 1.3).
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
Teach position
Teach position
Enter position
3 Calibration Functions User’s Manual Test Program SITEST
3.2 Calibration of the Component Camera Software Version 10.xx Edition 03/98
3 - 4
3.2 Calibration of the Component Camera
Carry out the preparatory steps proceeding as described in section 3.1 and section 3.1.1.
From the "Vision system" menu select the Component camera option and press the RETURN key. The
"Component camera" menu is displayed on the screen.
Overview of the Functions:
-
Calibrate camera to calibrate the component camera
-
Offset mech. c.stat. to determine the centering offset
-
Single seg. offset I to determine the segment offset of the selected segment in relation to the
component camera
-
All seg. offsets I to determine the segment offset of all 12 segments in relation to the component
camera
-
Display cam values to open the selection menu for the display of the coefficients and segment offset
values determined
-
More camera function Menu for starting additional camera functions
From the "Component camera" select the Calibrate camera function and press the RETURN key. The
calibration process is performed on the component camera of the active gantry.
NOTE
The values determined can be displayed after the calibration procedure has been completed by means of
the Display ca. coeffic. menu function of the "Display cam values" submenu.
Press the ESC key to return to the "Component camera" menu.
NOTE
At this point you can either save the data determined or, to save time, proceed directly with further calibration
operations.
However, be sure to save the calibration data (see section 3.12) , prior
to exiting from the SITEST program as
otherwise all data determined will be lost.
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
Component camera
Calibrate camera
Offset mech. c.stat.
Single seg. offset I
All seg. offsets I
Display cam. values
More camera function