User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 10.xx Edition 03/98 3.2 Calibration of the Component Camera
3 - 5
3.2.1 Further Component Camera Functions
From the "Component camera" menu select the
More camera function
option and press the RETURN
key. The "More camera function" menu is displayed on the screen.
Overview of the Functions:
-
Move to by nozzle to approach the calibration piece position with the revolver head
-
Move to by PCB-cam. to approach the calibration piece position with the PCB camera
-
Cali.tool in cam.pos to pick up the calibration piece and rotate it into the component camera’s field of
view
-
Return calibr. tool to deposit the calibration piece in the calibration piece pocket
-
Color conversion to switch the monitor to false-color display mode to view the results of changes in
illumination that may have been made
-
Center comp. mechan. to center the component in the mech. centering station
-
Modify illumination to display the illumination values "steep", "middle" and "top"
-
Camera number to open the input field for the camera number
(only required on lines with HS-180)
-
Send GF to MC to load GF data if data loss occurred
From the "More camera function" menu select the desired function or option, and press the RETURN key.
The selected function is executed, or the appropriate submenu opens (see, for example, section 3.2.1.1).
3.2.1.1 Changing the Illumination Values
NOTE
As a rule, any change in the illumination values is not
required. Changing the values in a non-expert manner will
result in incorrect calibration results.
From the "Component camera" menu select the
More camera function
option and press the RETURN
key. The "More camera function" menu is displayed on the screen.
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
Component camera
Calibrate camera
Offset mech. c.stat.
Single seg. offset I
All seg. offsets I
Display cam. values
More camera function
Move to by nozzle
Move to by PCB-cam.
Cali.tool in cam.pos
Return calibr. tool
Color conversion
Center comp mechan.
Modify illumination
Camera number
Send GF to MC
More camera function
3 Calibration Functions User’s Manual Test Program SITEST
3.3 Calibration of the PCB Camera Software Version 10.xx Edition 03/98
3 - 6
Select the
Modify illumination
menu option and press the RETURN key.
The "Modify illumination" input menu is now displayed on the screen.
Overview of the Functions:
-
Illumination steep steep illumination angle
-
Illumination middle medium illumination angle
-
Illumination flat flat illumination angle
Change the values as required and confirm your entries by pressing the RETURN key.
Exit from the input menu by pressing the ESC key.
Press the ESC key to return to the "Component camera" menu.
Repeat the calibration of the component camera proceeding as described in section 3.2.
Press the ESC key twice to return to the SITEST main menu.
3.3 Calibration of the PCB Camera
Carry out the preparatory steps proceeding as described in section 3.1 and section 3.1.1.
From the "Vision system" menu select the
PCB-camera
option and press the RETURN key. The "PCB-
camera" menu is displayed on the screen.
Overview of the Functions:
-
Calibrate camera to calibrate the PCB camera
-
Measure ca/ca.offset to check the offset from the PCB camera to the component camera
-
Move to by PCB-cam. to approach the fiducial position
-
Display ca. coeffic. to display the PCB camera values determined
-
Color conversion to switch the monitor to false-color display to view the results of changes in
illumination that may have been made
-
Camera number to open the input field for the camera number (required on lines with HS-180 only)
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
Component camera
Calibrate camera
Offset mech. c.stat.
Single seg. offset I
All seg. offsets I
Display cam. values
More camera function
Move to by nozzle
Move to by pcb-cam.
Cali. tool in cam.pos
Return calibr. tool
Color conversion
Center comp machan.
Modify illumination
Camera number
Send GF to MC
More camera function
Illumination steep
Illumination middle
Illumination flat
Modify illumination
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
PCB-camera
Calibrate camera
Measure ca/ca.offset
Move to by PCB-cam.
Display ca.coeffic.
Color conversion
Camera number
User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 10.xx Edition 03/98 3.3 Calibration of the PCB Camera
3 - 7
Select the
Calibrate camera
function and press the RETURN key.
The calibration procedure is performed on the PCB camera of the active gantry and is displayed on the
screen.
NOTE
The values thus determined can be displayed after the calibration procedure has been completed using
the
Display ca. coeffic.
function.
Press the ESC key to return to the "Vision system" menu.
3.3.1 Measuring the Offset Between PCB Camera and Component
Camera
Carry out the preparatory steps proceeding as described in section 3.1 and section 3.1.1.
From the "Vision system" menu select the
PCB-camera
option and press the RETURN key.
The "PCB-camera" menu is displayed on the screen.
From the "PCB-camera" menu select the
Measure ca/ca.offset
function and press the RETURN key.
The "Measure ca/ca.offset" menu is displayed on the screen.
Overview of the Functions:
-
Offset values to display the x and y-offset valued determined under "Segmentoffset
II
"
-
Measure offset to check the PCB/component camera offset
From the "Measure ca/ca.offset" menu select the
Measure offset
function and press the RETURN key.
The offset between the component camera and the PCB camera is measured.
NOTE
After the measuring procedure has been completed, the values determined can be displayed using the
Offset values
function.
Press the ESC key three times to return to the SITEST main menu.
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
PCB-camera
Calibrate camera
Measure ca/ca.offset
Move to by pcb-cam.
Display ca.coeffic.
Color conversion
Camera number
Offset values
Measure offset
Measure ca/ca.offset