User’s Manual Test Program S ITEST 3 Calibration Functions Software Version 10.xx Edition 03/98 3.8 Calibration of the IC-Camera (SIPLACE 80F) 3 - 13 3.8 Calibration of the IC-Camera (SIPLACE 80F) ● Carry out the prepa r…

100%1 / 88
3 Calibration Functions User’s Manual Test Program SITEST
3.7 Measuring the Position of the PCB Reference Corner Software Version 10.xx Edition 03/98
3 - 12
3.7 Measuring the Position of the PCB Reference
Corner
NOTE
Verify that the calibration data for the PCB camera, PCB/component camera offset and the machine zero
point have already been determined.
Load a PCB with a light surface into the center conveyor using the Functions --> Conveyor --> PCB in to
stopper menu options.
Press the ESC key repeatedly until only the SITEST main menu is displayed.
From the main menu select the Gantry positions option and press the RETURN key.
The "Gantry positions" menu is displayed on the screen.
Select the Calibrate menu item and press the RETURN key.
The "Calibrate" menu is displayed on the screen.
Select the Fixed PCB corner I function, press the RETURN key and the START button.
The PCB camera moves over the position of the PCB reference corner I.
The monitor switches to the PCB camera.
Teach the PCB reference corner position
I
using the cursor keys
↑↓ ← →
.
(For details on the procedure for traversing the gantry during teaching, see section 0.4.1).
Terminate the teaching operation by pressing the ESC key.
The monitor switches back to the normal program mode, and the current position is adopted as the refe-
rence corner position.
Press the ESC key twice to return to the SITEST main menu.
Transport the PCB into the output conveyor using the Functions --> Conveyor --> PCB out menu
options.
Press the ESC key twice to return to the SITEST main menu.
NOTE
Only
the values for "Zero point cor. value", "Minimal position" and "Maximal position" that were modified in
the "Positions" input menu can be saved with the aid of the main menu option File Manager --> Store
MA-file. All other modified axis data cannot
be saved. They will be reset to the original values upon exiting
from the SITEST program
.
User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 10.xx Edition 03/98 3.8 Calibration of the IC-Camera (SIPLACE 80F)
3 - 13
3.8 Calibration of the IC-Camera (SIPLACE 80F)
Carry out the preparatory steps proceeding as described in section 3.1 and section 3.1.1.
From the "Vision system" menu select the
IC-camera
option and press the RETURN key.
The "IC-camera" menu is displayed on the screen.
Overview of the Functions:
-
Move to by pcb-cam. to approach the calibration piece position with the PCB camera
-
Move to by IC-head to approach the calibration piece with the IC-head (nozzle "416" or "417")
-
IC-ca.pos & offset to determine the camera position in x and y-directions and determination of the
distance between IC-nozzle and the component camera.
-
Calibrate IC-camera to calibrate the IC-camera
-
Illumination test menu for the performance of the illumination test
-
Illumination for GF not available
-
Meas.focus camera Menu for measuring the focus position of the of the IC-camera
-
Illumination values to display the illumination values "steep", "middle" and "flat"
-
Calibration factors to display the IC-camera values determined
-
Camera number to open the input field for the camera number
(only required for lines with HS-180)
From the "IC-camera" menu select the
Meas.focus camera
option and press the RETURN key.
The "Meas.focus camera" menu is displayed on the screen.
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
IC-camera
Move to by pcb-cam.
Move to by IC-head
IC-ca.pos & offset
Calibrate IC-camera
Illumination test
Illumination for GF
Meas.focus camera
Illumination values
Calibration factors
Camera number
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
IC-camera
Move to by pcb-cam.
Move to by IC-head
IC-ca.pos & offset
Calibrate IC-camera
Illumination test
Illumination for GF
Meas.focus camera
Illumination values
Calibration factors
Camera number
Meas.focus camera
Pick up cal. tool
Return cal. tool
Measure focus
Measure z-Delta
Focus pos. (digit)
3 Calibration Functions User’s Manual Test Program SITEST
3.8 Calibration of the IC-Camera (SIPLACE 80F) Software Version 10.xx Edition 03/98
3 - 14
Overview of the Functions:
-
Pick up cal. tool to pick up the calibration piece with the IC-head
-
Return cal. tool to deposit the calibration piece in the calibration piece pocket
-
Measure focus to measure the focus position
-
Measure z-Delta to determine the z-delta (from the conveyor top edge to the focus position of the
IC-camera)
-
Focus pos. to display the measured focus position
From the "Meas.focus camera" menu select the
Pick up cal. tool
function and press the RETURN key.
The IC-head picks up the calibration piece with the nozzle and moves over the IC-camera.
Select the
Measure focus
function and press the RETURN key.
Using the cursor keys
↑↓
adjust the calibration piece until its sharply defined image is displayed on the
screen.
Actuate the cursor key
repeatly until the calibration piece appears blurred. Note down the current z-axis
position (SIPLACE axis tester, axis 6, see "Service manual SIPLACE).
Actuate the cursor key
repeatly until the calibration piece appears blurred. Note down the current z-axis
position (SIPLACE axis tester, axis 6, see "Service manual SIPLACE).
Determinate the mean value of these two z-axis positions.
Using the cursor keys
↑↓
position the axis to the mean value position. The calibration piece must appear
on the screen sharply defined.
Press the ESC key to return to the "IC camera" menu. Switch the monitor back to the normal program
mode.
Select the
Measure z-Delta
function and press the RETURN key.
The value thus determined is displayed on the screen.
Select the
Return cal. tool
function and press the RETURN key.
The IC-head deposits the calibration piece in the calibration piece pocket.
Press the ESC key to return to the "IC-camera" menu.
Select the
Calibrate IC-camera
function and press the RETURN key.
The calibration operation is performed on the IC-camera.
Select the
IC-ca.pos & offset
function and press the RETURN key.
The "IC-ca.pos & offset" menu is displayed on the screen (see section 3.8.2).
From the "IC-ca.pos & offset" menu select the
Measure
function and press the RETURN key.
The offset between IC-head and component camera and the position of the IC-camera are measured.
If you wish to view the values determined after the calibration procedure has been completed, select the
Calibration factors
menu function and press the RETURN key.
The values determined are displayed.