User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 10.xx Edition 03/98 3.8 Calibration of the IC-Camera (SIPLACE 80F)
3 - 15
3.8.1 Changing the Illumination Values
NOTE
As a rule, changing the illumination values is not
required. Any change in the values performed in a non-expert
manner will result in incorrect calibration results.
●
From the "IC-camera "menu select the
Illumination values
option and press the RETURN key.
The "Illumination values" input menu is displayed on the screen.
Overview of the Functions:
-
Illumination steep steep angle of illumination
-
Illumination middle medium angle of illumination
-
Illumination flat flat angle of illumination
●
Change the values as required and confirm your entries by pressing the RETURN key.
●
Exit from the input menu by pressing the ESC key.
●
Repeat the calibration of the IC-camera as described in section 3.8.
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
IC-camera
Move to by pcb-cam.
Move to by IC-head
IC-ca.pos & offset
Calibrate IC-camera
Illumination test
Illumination for GF
Meas.focus camera
Illumination values
Calibration factors
Camera number
Illumination values
Illumination steep
Illumination middle
Illumination flat

3 Calibration Functions User’s Manual Test Program SITEST
3.8 Calibration of the IC-Camera (SIPLACE 80F) Software Version 10.xx Edition 03/98
3 - 16
3.8.2 Measuring the Offset From IC-Head to Component Camera and
IC-Camera Position
NOTE
Verify that the calibration data for the PCB camera, IC-camera and PCB/component camera offset have
already been determined.
●
Carry out the preparatory steps proceeding as described in section 3.1 and section 3.1.1.
●
From the "Vision system" menu select the
IC-camera
option and press the RETURN key. The "IC-camera"
menu is displayed on the screen.
●
From the "IC-camera" menu select the
IC-ca.pos & offset
function and press the
RETURN key. The "IC-ca.pos & offset" menu is displayed on the screen.
Overview of the Functions:
-
Camera position to display or enter the x and y-position of the IC-camera
-
IC-Camera Offset to display or enter the x and y-offset of IC-head to component camera
-
Measure to determine the offset between IC-head and component camera in x and
y-directions and to determine the IC-camera position
●
From the "IC-ca.pos & offset" menu select the
Measure
function and press the RETURN key.
The offset between IC-head and component camera and the position of the IC-camera is measured.
NOTE
Following the completion of the measuring operation the values determined can be displayed on the
screen using the
IC-Camera offset
function.
●
Press the ESC key to return to the SITEST main menu.
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
IC-camera
Move to by pcb-cam.
Move to by IC-head
IC-ca.pos & offset
Calibrate IC-camera
Illumination test
Illumination for GF
Meas.focus camera
Illumination values
Calibration factors
Camera number
IC-ca.pos & offset
Camera position
IC-Camera offset
Measure

User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 10.xx Edition 03/98 3.9 Calibration of the Flip-Chip Camera (SIPLACE 80F)
3 - 17
3.9 Calibration of the Flip-Chip Camera (SIPLACE 80F)
●
Carry out the preparatory steps proceeding as described in section 3.1 and section 3.1.1.
●
From the "Vision system" menu select the Flip-chip-camera option and press the RETURN key.
The "Flip-chip-camera" menu is displayed on the screen.
Overview of the Functions:
-
Camera position Menu for entering or determining the Flip-Chip camera position
-
Calibrate camera to calibrate the Flip-Chip camera
-
Meas.focus camera Menu for measuring the focus position of the Flip-Chip camera
-
Calibration factors to display the Flip-Chip camera values determined
-
Camera number to open the input field for the camera number
●
From the "Flip-chip-camera" menu select the Meas.focus camera option.
The "Meas.focus camera" menu is displayed on the screen.
Overview of the Functions:
-
Pick up cal. tool to pick up the calibration piece with the IC-head
-
Return cal. tool to deposit the calibration piece in the calibration piece pocket
-
Measure focus to measure the focus position
-
Measure z-Delta to determine the z-delta
(from conveyor top edge to focus position of Flip-Chip camera)
-
Focus pos. to display the focus position measured
-
z step size (digit) to enter or modify the z step size for the focus adjustment
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
Flip-chip camera
Camera position
Calibrate camera
Meas.focus camera
Calibration factors
Camera number
Pos.calibration tool
Adopt current pos.
Teach position
PCB-camera
Component camera
IC-camera
Flip-chip-camera
Vision system
Flip-chip camera
Camera position
Calibrate camera
Meas.focus camera
Calibration factors
Camera number
Meas.focus camera
Pick up cal. tool
Return cal. tool
Measure focus
Measure z-Delta
Focus pos. (digit)
z step size (digit)