00191174-01.pdf - 第74页
3 Calibration Functions User’s Manual Test P rogram SITEST 3.12 Saving the Calibration Data Software Version 10.xx Edition 03/98 3 - 26 3.12 Saving the Calibration Data ● To save the valu es determ ined, sel ect from the…

User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 10.xx Edition 03/98 3.11 Calibration of the Nozzle Changer
3 - 25
●
To determine the pick-up height (z-height), select the
Return nozzle
function and press the RETURN key.
The nozzle is returned to the nozzle changer compartment.
●
Next, select the
Pick up nozzle
function and press the RETURN key.
The nozzle is picked up.
If the nozzle is not properly returned and then picked up again, you can change the values for the pick-up
positions.
●
Select the
Positions
menu item. The "Positions" input screen opens.
●
Change the values, as required, and confirm your entries by pressing the RETURN key.
●
Press the ESC key to return to the "*Noz.changer IC-head" menu.
●
To verify the changed positions, select the
Return nozzle
function and press the RETURN key. The
nozzle is returned to the nozzle changer compartment.
●
Next, select the
Pick up nozzle
function and press the RETURN key.
The nozzle is picked up.
(The steps described above may have to be repeated if the nozzle is, once more, not properly returned
and picked up.)
NOTE
The values for the "pick-up angle" and the "z-position" can be saved to the "REAL.MA" file via the
File
Manager
-->
Store MA-file
main menu option (see section 1.3).
●
Press the ESC key three times to return to the SITEST main menu.
Functions
Conveyor
CRDL tester
Component-table
Nozzle changer
Coplanarity function
Movable conv. side
Width adjustment
Calibrate nozzle cha
Show nozzle cahn. da
Nozzle changer
RV-Pipw.Funktionen
IC-Pipw.Funktionen
Cal.noz.chang.compl.
Calibr. fiducial 1
Calibr. fiducial 2'
Disp. nozzle position*
Pick up nozzle
Return nozzle
Garage [1..20]
Positions
Noz.changer IC-head
zPos. axis down Test xxxx
d pos. for pick-up T xxxxx
d pos. for locking T xxxxx
Pick-up angle (*.ma) xxxx
z-Position (real.ma) xxxxx
Positions

3 Calibration Functions User’s Manual Test Program SITEST
3.12 Saving the Calibration Data Software Version 10.xx Edition 03/98
3 - 26
3.12 Saving the Calibration Data
●
To save the values determined, select from the SITEST main menu the File Manager option and press the
RETURN key. The "File Manager" menu opens (see section 1.3).
●
Select the Store MA-file function and press the RETURN key.
The values determined are saved to the "REAL.MA" file.
●
Press the ESC key to return to the SITEST main menu.
NOTE
Only
the values for "Zero point cor. value", "Minimal position" and "Maximal position" that were modified in
the "Positions" input menu can be saved with the aid of the main menu option File Manager --> Store
MA-file. All other modified axis data cannot
be saved. They will be reset to the original values upon exiting
from the SITEST program
.

User’s Manual Test Program SITEST
Software Version 10.xx Edition 03/98
4 - I
Contents
Page
Mapping
4.1 Preparatory Steps for the Mapping Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 1
4.1.1 PCB Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 - 2
4.1.2 RV-Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 - 6
4.1.3 IC-Mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 - 8