00191174-01.pdf - 第81页
User’s Manual Test Program S ITEST 4 Mapping Software Version 10.xx Edition 03/98 4.1 Preparatory Steps for the M apping Operation 4 - 5 ● Select the Select gantry menu option a nd press the RE TURN key. The "S elec…

4 Mapping User’s Manual Test Program SITEST
4.1 Preparatory Steps for the Mapping Operation Software Version 10.xx Edition 03/98
4 - 4
NOTE
Each mapping plate is delivered with a diskette containing a measured values file. This file contains the
values of the deviation of the measuring points from their setpoint positions. These values are required for
PCB mapping for correction purposes. Following the input of the plate number (see below) the measured
values file is read in from diskette and only thereafter can the PCB mapping run be started.
●
Place the diskette supplied with the mapping plate into the floppy disk drive.
●
From the "PCB-mapping" menu select the
Mapp.-plate number
option and press the RETURN key. The
"Mapp.-plate number" input menu opens.
●
Enter the mapping plate number, confirm your entry by pressing the RETURN key and press the ESC key
to return to the "PCB-mapping" menu.
The measured values file associated with the mapping plate is read in.
The "Mapping run", "Mapping cont. run" etc. options can now be selected.
●
Select
Mapping run
function and press the RETURN key. The active gantry performs the mapping run.
After the mapping run is completed, the data determined will be automatically saved.
NOTE
On SIPLACE 80S machines it is good practice to select the
Mapp. both gantries
function instead of the
Mapping run
function so that the mapping run is performed for both gantries without
having to switch from
gantry 1 to gantry 2 (Select gantry). When the mapping run of gantry 1 is completed, gantry 1 is automatically
moved to the park position and subsequently the mapping run for gantry 2 is performed.
●
To review the mapping data determined, select the
Display mapping data
function and press the
RETURN key. The data determined are displayed on the screen.
NOTE
To increase the accuracy of the mapping run, the values measured are compared with each measuring
point (position). The maximum permissible deviation (delta) of the measured values determined during the
current measurement run must not be exceeded in comparison with the previous measurement.
When PCB mapping is completed, the number of the positions that did not comply with these require-
ments is displayed.
●
Press the ESC key three times to return to the SITEST main menu.
NOTE
The procedure described below is only required if on a SIPLACE 80S the PCB mapping procedure is per-
formed by means of the
Mapping run
function
rather than the
Mapp. both gantries
function.
CAUTION
∆
!
Move gantry 1 to the park position using the menu functions of the "Gantry positions" menu (see
section 3.5).

User’s Manual Test Program SITEST 4 Mapping
Software Version 10.xx Edition 03/98 4.1 Preparatory Steps for the Mapping Operation
4 - 5
●
Select the
Select gantry
menu option and press the RETURN key.
The "Select gantry" menu opens.
●
Select the
gantry 2 active
for gantry 2 and press the RETURN key.
●
Press the ESC key to return to the SITEST main menu.
NOTE
When switching from one gantry to the other make sure that the position of the mapping plate is not
changed.
●
From the main menu select the
Mapping
option and press the RETURN key.
The "Mapping" menu is displayed on the screen.
●
From the "Mapping" menu select the
PCB-mapping
function and press the RETURN key.
The "Mapping" menu is displayed on the screen.
●
Select the
Mapping run
function and press the RETURN key. The active gantry performs the mapping
run. When the mapping run is completed, the data determined will automatically be saved.
●
Remove the mapping plate for PCB mapping.
●
Press the ESC key twice to return to the SITEST main menu.
NOTE
Do not
terminate your SITEST program session, but subsequently perform PCB mapping and in the case of
SIPLACE 80F machines, also IC-mapping.

4 Mapping User’s Manual Test Program SITEST
4.1 Preparatory Steps for the Mapping Operation Software Version 10.xx Edition 03/98
4 - 6
4.1.2 RV-Mapping
NOTE
Prior to the performance of RV-mapping make sure that PCB mapping has already been carried out.
The SITEST program must not have been restarted following PCB mapping.
●
Carry out the preparatory steps as described in section 4.1.
Additional prerequisites are:
-
both gantries must be in the park position.
-
segment offset
I
and
PCB/component camera offset must already have been determined for both
gantries.
-
the calibration piece must be in the calibration piece pocket.
-
the calibration piece position must already have been determined.
-
on segment 1 of each revolver head a size 617 nozzle must be attached.
●
From the main menu select the
Mapping
option and press the RETURN key.
The "Mapping" menu is displayed on the screen.
●
Select the
RV-mapping
function and press the RETURN key.
The "RV-mapping" menu is displayed on the screen.
Overview of the Functions:
-
RV-mapping to perform the RV-mapping
-
Cont. RV-mapping to perform mapping in the continuous run mode until the continuous run is aborted
by pressing ESC
Display mapping data to display the mapping data determined
-
Mapping data ct. run to display the data determined in the continuous mapping run
-
Continue RV-mapping to continue mapping from the measuring point entered
-
Mapp. both gantries to perform the mapping run for both gantries of SIPLACE 80S
(MC-changeover is carried out automatically. The mapping run is first performed
for gantry 1, thereafter for gantry 2.)
●
From the "RV-mapping" menu select the
RV-mapping
function and press the RETURN key. The active
gantry performs the mapping run. The measured values are automatically stored after the completion of
this mapping run.
Mapping
Mapping mode
PCB-mapping
RV-mapping
IC-mapping
Read mapping file
RV-mapping
RV-mapping
Cont. RV-mapping
Display mapping data
Mapping data ct. run
Continue RV-mapping
Mapp. both gantries