00193826-01 - 第53页

User Manual SIPLAC E CS 2 Operational safety Software version SR.101.xx 06/2003 US Edition 2.7 Disabling the compressed air supply and discharging the pressure 53 2.7 Disabling the compress ed air supply a nd discharg- i…

100%1 / 160
2 Operational safety User Manual SIPLACE CS
2.6 Residual voltages and discharge times in the machine Software version SR.101.xx06/2003 US Edition
52
2.6.1 Operating voltages, residual voltages and discharge times after pressing
the emergency stop button
2
2.6.2 Residual voltages and discharge times after switching off at the main switch
2
CAUTION
To avoid losing data, evaluate the following criteria before switching off your automatic placement
system (apart from in emergencies):
Has the placement system finished transmitting machine, setup and panel data?
Has the placement system finished processing the PCB?
Has the placement system completed the run-up phase?
Has the Windows XP operating system been shut down correctly? 2
Test socket 00X
measured at 007 (GND)
Voltage in
normal mode
Residual
voltage after
EMERG. STOP
Discharge times of
electrolytic
capacitors at 12 VDC
001 70 VDC 10 VDC < 2 sec
002 30 VDC 30 VDC
003 30 VDC < 12 VDC < 2 sec
004 24 VDC 24 VDC
005 12 VDC 12 VDC
006 5 VDC 5 VDC
008 70 VDC 10 VDC < 2 sec
009 155 VDC 10 VDC < 1 sec
Tab. 2.6 - 1 Operating voltages, residual voltages and discharge times after pressing the emergency stop button
Test socket 00X
measured at 007 (GND)
Residual voltage when
main power switch is off
Discharge times of electrolytic
capacitors at 12 VDC
001 < 12 VDC < 2 sec
002 < 12 VDC < 2 sec
003 < 12 VDC < 2 sec
004 0 VDC
005 0 VDC
006 0 VDC
008 < 12 VDC < 2 sec
009 < 12 VDC < 1 sec
Tab. 2.6 - 2 Residual voltages and discharge times after switching off at the main switch
User Manual SIPLACE CS 2 Operational safety
Software version SR.101.xx 06/2003 US Edition 2.7 Disabling the compressed air supply and discharging the pressure
53
2.7 Disabling the compressed air supply and discharg-
ing the pressure
Fig. 2.7 - 1 Compressed air unit on the placement system
2
(1) Shutoff valve lever in the CLOSED position
(2) Working pressure gauge
(3) Solenoid valve for venting the tape cutter during an EMERGENCY STOP
(4) Pressure gauge for the PCB stopper working pressure
(5) Compressed air supply, gantry 2
(6) Compressed air supply, gantry 1
(7) Position of the compressed air unit
WARNING Never disconnect compressed air lines while they are pressurized. 2
CAUTION
When the machine is switched on, do not use the stop valve to interrupt the compressed air sup-
ply for more than 30 minutes. If you need to shut off the pneumatic system for longer in order to
carry out preventive maintenance or servicing work, you must switch the placement system off at
the main switch and disconnect it from the power supply.
2 Operational safety User Manual SIPLACE CS
2.7 Disabling the compressed air supply and discharging the pressure Software version SR.101.xx06/2003 US Edition
54
The compressed air working pressure is set to 0.52 MPa (5.2 bar). It may fluctuate between
0.5 MPa (5.0 bar) and 0.53 MPa (5.3 bar). The position of the compressed air unit is indicated by
item 5 in Fig. 2.7 - 1
. The compressed air supply to the machine can be interrupted using the
shutoff valve (item 1 in Fig. 2.7 - 1
).
You must remove the cover plate to use the shutoff valve.
Turn the lever on the shutoff valve (item 1 in Fig. 2.7 - 1
) from the vertical to the horizontal po-
sition.
Watch the working pressure gauge (item 2 in Fig. 2.7 - 1
) and the pressure gauge for the com-
pressed air supply to the stopper (item 4 in Fig. 2.7 - 1
). When the automatic placement system
is switched on, the pressure discharges to 0 MPa (0 bar) within 1 minute.