00195425-01 - 第11页

Ins tall ati on and Confi gurat ion G uid e SIPL ACE E xplo rer 1 Int roduc tio n Edi tion 05 /200 7 EN 1. 3 Addit iona l Remar ks 11 1.3 Additio nal Re marks SIPL ACE Explorer V ersion 2.2 has the following restriction …

100%1 / 128
1 Introduction Installation and Configuration Guide SIPLACE Explorer
1.2 System Requirements Edition 05/2007 EN
10
MS Internet Explorer 6.0 SP1,
included on the Support Media DVD
Acrobat Reader 7.0
included on the Support Media DVD
1.2.3 Supported Data Sources
SIPLACE Explorer V2.2 supports data from the following SIPLACE products: 1
OIS 5.0, SIS 5.0, SIPLACE Pro 5.0
OIS 4.1, SIS 4.1, SIPLACE Pro 4.1
OIS 4.0, SIS 4.0, SIPLACE Pro 4.0
OIS 3.1, SIS 3.1, SIPLACE Pro 3.2
The following versions are supported but if problems should occur, you will need to update these
versions to those shown above. 1
OIS2.4 SP1, SIS 1.2 SP1, SIPLACE Pro 2.1 SP2
SIPLACE Explorer V2.2 supports data from the following station software versions: 1
SW 604
SW 602.01
SW 601.03 SP 1
SW 505.03 SP 1
SW 407.04 SP 1
SW 408.01
The following version is supported but if problems should occur, you will need to update it to the
version shown above. 1
SW 503.04 SP 2; This version is only suitable if an update to SW 505.03 SP 1 is not possible
due to hardware restrictions.
Installation and Configuration Guide SIPLACE Explorer 1 Introduction
Edition 05/2007 EN 1.3 Additional Remarks
11
1.3 Additional Remarks
SIPLACE Explorer Version 2.2 has the following restrictions: 1
SIPLACE Explorer V2.2 is unable to use data from SIS for boards which are marked as "SA"
(stand-alone). This means that the following information is not available for boards marked with
"SA":
Component name
Component shape
Feeder type
The following SMA pages show limited data due to the "Stand-alone" mode: 1
Pickup Reliability
Pickup Summary
–Reject Rate
Transition Log
Factory Layout:
A SIPLACE Explorer host (the computer on which SIPLACE Explorer "Runtime Environment"
is installed) can monitor five production lines with up to 20 stations.
Single Line Layout
A SIPLACE Explorer host (the computer on which SIPLACE Explorer "Runtime Environment"
is installed) can monitor one production line with up to 7 stations.
For performance reasons, we recommend that you do not generate reports for all websites and
report types at once. Try to run the report generation at a time when there is no production op-
eration e.g. at the weekend.
From SIPLACE Explorer Version 2.0 SP1, the station GEM interface will no longer be sup-
ported i.e. data can not be recorded via the GEM interface with SIPLACE Explorer Version 2.2
or higher. If you need support for the GEM interface, please contact the SIPLACE Hotline.
The system time on the connected machines and that belonging to the SIPLACE Explorer must
be synchronized. SIPLACE machines require the installation of TimeSync, which is included
on the Support Media DVD provided with the delivery.
The standard SIPLACE Explorer 2.2 delivery package includes support tools for SIPLACE ma-
chines. These include all machines which have been previously listed in the version descrip-
tion, see "Software Version Description SIPLACE Explorer 2.2, Art. No. 00195426-01.
Support for other equipment, such as screen printers or reflow ovens, is not part of the stan-
dard SIPLACE Explorer product package.
If you want to monitor screen printers and reflow ovens with SIPLACE Explorer, this will need
1 Introduction Installation and Configuration Guide SIPLACE Explorer
1.3 Additional Remarks Edition 05/2007 EN
12
to be realized as a customer-specific project.
There is a special OIS status module realized in SIPLACE OIS. This OIS status module is
shown in the SIPLACE Explorer status module which matches the SEMI E10 status module.
This may lead to deviations in the states and status times shown between OIS and SIPLACE
Explorer. A direct comparison is therefore not possible.
The following restriction applies to platform I (S20, S23, F4, F5, F5HM) stations with dual con-
veyors:
The page Production Summary will display Unknown in the Current Recipe List table for
the 2nd conveyor lane. 1
Reason:
Platform I stations are unable to produce different recipes, even with dual conveyors. There-
fore, only one recipe will be loaded for the SIPLACE line. This recipe will then only be assigned
to conveyor lane I by SIPLACE Explorer. 1
The following restrictions apply to the SMA pages listed below, if no boards are placed at the
last station in the production line:
The page Production Summary will not update the values in the column Lot Progress of
the table Lot Progress, if the last station in the production line does not have any place-
ment contents for the recipe currently defined. In this case, the last station will conveyor the
boards through without placement. The column Lot Progress will continue to show the
name of the last recipe which had placement contents at the last station.
Machine Navigator:
OLE value will not be shown (N/A).
Overview of OLE / OEE:
Overall Line Efficiency diagram: Values for OLE, performance and availability will not be
shown correctly.
Overall Equipment Efficiency by Station diagram: station data is not shown correctly for
stations which do not place boards.
OEE Analysis:
Table: values for performance and availability will not be shown correctly for lines and sta-
tions which do not place boards.
Overall Equipment Efficiency diagram – comparison diagram: Values for OLE, performance
and availability will not be shown correctly for the line.
Factory Overview
The following values will not be shown correctly or will not be updated:
OLE, Current Recipe/ Job, Last Recipe Change, Completed, Lot Progress, Average Takt
Time.