00197490-03_SM_CP20-P-M2_EN保养维护 - 第39页

5 DP drives 5.1 Replacing the DP drive Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018 39 5 DP drives 5.1 Replacing the DP drive Parts Fig.44: DP drive (example of SIPLACE C&P20P shown) Select…

100%1 / 88
4 Component camera, Z axis and component sensor
4.5 Replacing the component sensor
38 Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018
Installation
Fix the new component sensor with the two fastening screws.
Plug in the electrical connection. Fasten the cable with cable ties, if required.
Follow the removal instructions in reverse order for further installation.
Also observe the installation instructions in the following section:
4.2 "Replacing the Z axis cover" [}29]
Observe in particular the torques specified!
Calibrate the component sensor.
11.2.1 "Calibrating the heads and cameras (SW70x)" [}84]
5 DP drives
5.1 Replacing the DP drive
Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018 39
5 DP drives
5.1 Replacing the DP drive
Parts
Fig.44: DP drive (example of SIPLACE C&P20P shown)
Select the correct DP drive:
For SIPLACE C&P20P:
DP drive SIPLACE C&P20P [03102532Sxx] (in-
cluding accessories)
For SIPLACE C&P20M2:
DP drive SIPLACE C&P20M2 assembly
[03153682Sxx] (including accessories)
If needed: DP vacuum hose for SIPLACE C&P20P [03103784‑xx]
Overview
Fig.45: DP drive (example of SIPLACE C&P20P shown)
1. Board
2. Connection for compressed air supply
3. Linear guide
4. End stop edge
5. Fastening screw
6. Fastening screw
Fig.46: DP change tool
DP change tool for the SIPLACE C&P20P
[03109065‑xx]
The DP change tool makes it easier to fit the DP drive
in the placement head.
5 DP drives
5.1 Replacing the DP drive
40 Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018
Torques
Fig.47: Clamping plate fastening screw
1. Clamping plates
2. Screw fastening the clamping plate
Torque: 0.1Nm
Preparation
Remove the head from the machine. For details about removing and fitting the placement
head, refer to the service manual for your machine.
Fit the head on the head mount [03056231‑xx].
Make sure that the component sensor protective cap is fitted.
1.1.3 "Safety instructions for the component sensor" [}6]
Removal
CAUTION
Tweezers, blunt 145mm size 3mm [00376493-xx]
Do not use any other tweezers for the hoses. If you do, the hoses could be damaged.
Dismantle the holding circuit/aperture ring.
7.1 "Replacing the holding circuit/reflecting ring" [}61]
Pull the nozzle off the segment.
Fig.48: Clamping plates
Remove the screws(2) fastening the clamping
plates(1), on the right and left of the relevant DP
drive and take off the clamping plates.