00197490-03_SM_CP20-P-M2_EN保养维护 - 第47页

6 Pressure control valve (PRV) 6.1 Replacing the PRV Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018 47 6 Pressure control valve (PRV) 6.1 Replacing the PRV Parts ● Pressure control valve (PRV) [031…

100%1 / 88
5 DP drives
5.3 Replacing the clamping plate at the DP drive
46 Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018
6 Pressure control valve (PRV)
6.1 Replacing the PRV
Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018 47
6 Pressure control valve (PRV)
6.1 Replacing the PRV
Parts
Pressure control valve (PRV) [03106620‑xx]
Overview
Fig.58: Pressure control valve fastening screws
1. Pressure control valve (PRV)
2. Two fastening screws
Torque: 0.9Nm
Fig.59: Overview of PRV
1. Strain relief with intermediate plate
2. Energy and data supply
3. Compressed air connection
4. Vacuum/air blast for pickup/placement circuit
5. Exhaust air, for cooling the X linear motor
6. Fastening screws on PRV
The pressure control valve supplies the pickup/place-
ment circuit with vacuum during the pickup process
and switches over to air blast during placement.
Preparation
Remove the head from the machine. For details about removing and fitting the placement
head, refer to the service manual for your machine.
Fit the head on the head mount [03056231‑xx].
Make sure that the component sensor protective cap is fitted.
1.1.3 "Safety instructions for the component sensor" [}6]
6 Pressure control valve (PRV)
6.1 Replacing the PRV
48 Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018
Removal
Fig.60: Disconnecting the energy and data supply cable
Remove the two screws fastening the strain re-
lief(1) and then remove the strain relief (2).
Press the two locks(3) together and unplug the
energy and data supply cable(4).
Open the cable clamp fastening the cable to the component camera.
Disconnect the hoses to the compressed air and from the vacuum/blast air and exhaust air. If
necessary, mark their positions to make clear assignment easier later on.
Remove the two screws fastening the PRV and then remove the PRV.
Installation
Fit the new PRV. Tighten the screws fastening the PRV with a torque of 0.9Nm.
Reconnect to the electrical and compressed air systems.
Pay attention to the locking of the connectors.
Follow the removal instructions in reverse order for further installation. Also observe the fol-
lowing instructions:
CAUTION
Installation instructions
Perform "zero correction" for the pressure control valve. (See section 6.4 "Calibrating
the digital PRV" [}60]).