00197490-03_SM_CP20-P-M2_EN保养维护 - 第9页

1 Introduction 1.2 Other instructions Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018 9 Edition Amendments 03/2018 Amendments and supplements ● General – Integration of usability upgrade (including …

100%1 / 88
1 Introduction
1.2 Other instructions
8 Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018
1.2.4.5 Dispatching ESD modules
Always store modules and components in conductive packaging (e.g. metalized plastic bags
or metal sleeves) and dispatch them in conductive packaging.
If the packaging is not conductive, place the modules in a conductive envelope before pack-
aging. Use conductive expanded rubber, ESD bags, domestic aluminium foil or paper, for ex-
ample. NEVER use plastic bags or film.
If the module has integral batteries, ensure that the conductive packaging does not touch or
short-circuit the battery terminals and, if necessary, first cover the terminals with insulating
tape or material.
1.2.5 Validity of document
This document contains service work instructions for all SIPLACE C&P20 P and C&P20 M2 place-
ment head types.
The service work described in this manual is largely identical for all placement heads:
If the work required should differ from the standard procedure, this will be indicated with refer-
ence to the head type and/or the serial number.
Diagrams should be seen as examples e.g. the diagram of a different paint finish does not
mean that the following information only applies to the type shown.
The manual focuses on describing mechanical service work.
Please refer to the circuit diagram folder for any electrical checks.
1.2.6 Release history
Document
SIPLACE Speedstar
(C&P20P / C&P20M2)
Service manual
Edition Amendments
12/2013 Initial release
09/2014 Amendments and supplements:
Torque screwdriver; note for vacuum pump/compressed air mode on X‑SeriesS ma-
chines; protective cap for sensor; aperture ring/holding circuit; new board for interme-
diate distributor; new component cameras; hose on DP drive; sealing system for DP
drive no longer applies; Z axis cover; calibration of digital pressure control valve; va-
cuum sensor board for holding circuit of SIPLACE C&P20P
1 Introduction
1.2 Other instructions
Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018 9
Edition Amendments
03/2018 Amendments and supplements
General
Integration of usability upgrade (including new handle, assembly markings,
board cover)
Revision of document structure
Revision of tools needed
Integration of SIPLACE C&P20M2
Integration of technical information
New screenshots for software
Introduction
Update of safety instructions
Safety instructions for the component sensor (new section)
SIPLACE in the World Wide Web (update)
Abbreviations (additions)
Tools required, measuring equipment and materials (new section)
Overview of the modules
Overview of parts for SIPLACE C&P20 P (update)
Usability package (new section)
Z axis, component camera and component sensor
Component camera (new camera types, fastening screws, running cables,
board cover)
Z axis cover (update, torques)
Component sensor (update, cable ties, calibration)
Neodym magnets (new section)
DP drives
DP drive (update, new DP drives for the SIPLACE C&P20 M2)
Pressure control valve (PRV)
PRV (update, new item number, locks)
Membrane and other small parts on the PRV (new section)
Exhaust air hose (new section)
Calibrating the digital PRV (update)
Holding circuit, aperture ring and silencer
Holding circuit/aperture ring (update, new item number)
Board for holding circuit vacuum sensor (new section)
Return unit and return cylinder
Return unit (update, torque, board cover)
Driver lever (update, torque)
Intermediate distributor
Board for intermediate distributor (update, new ID for the SIPLACE
C&P20M2, board cover)
Miscellaneous
Handle (new section)
1 Introduction
1.3 Staff qualifications and training
10 Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018
1.2.7 SIPLACE on the World Wide Web (WWW)
Log into our SIPLACE® homepage at www.asm-smt.com.
You can choose between the German and English versions.
The different sections contain information about our products, services and contact persons.
In addition, registered customers can also access the MySIPLACE user group. Here you can call
up special information about our placement systems, e.g.
technical documentation
technical information
spare parts lists etc.
Registration for theMySIPLACE user group is very simple:
Click at the head of the web site on
and then on the Register
link.
Fill in the registration form and send it off to us.
Soon afterwards, you will receive your access authorization with user name and password
1.3 Staff qualifications and training
Qualified or adequately trained personnel means that these people are familiar with the setting up,
operation and maintenance of the machine and the add-on devices and are suitably qualified, e.g.:
Have been trained, instructed or authorized to switch on and off, isolate, earth and identify
electrical circuits and system components in accordance with normal safety standards.
Have been trained or instructed in the upkeep and use of appropriate safety equipment in
accordance with normal safety standards.
Have received first aid training.
1.4 Abbreviations
Abbreviation Description
PA, PA1, PA2 Placement area, Placement area 1, Placement area 2
CO Component
CP Collect&Place
C&P20, CP20 Collect&Place head with 20 segments
C&P20/A/M Collective term for C&P20, C&P20 A and C&P20 M
C&P20 P/M2 Collective term for C&P20 P and C&P20 M2
ESD Electrostatic sensitive device
EMC Electromagnetic compatibility
FHE Fast Head Exchange
PCB PCB Board
HMK Head Maintenance Kit
P&P Pick&Place
SCS Single Core Solution
SC Station computer
VS Vision system type
ID Intermediate distributor