6 Aperture ring, holding circuit and silencer
6.1 Replacing the aperture ring/holding circuit/sealing disc
Service Manual SIPLACE SpeedStar (C&P20 P2) 01/2019 45
6 Aperture ring, holding circuit and silencer
See also
2 9.3 "Replacing the holding circuit board" [}71]
6.1 Replacing the aperture ring/holding circuit/sealing disc
Parts – vacuum operation
Fig.56: Aperture ring
1 03165750-xx Aperture ring assembly SIPLACE C&P20 P2 (including sealing disc and
cover)
2 03006234-xx O-Ring 40x1.5
3 03105638-xx Sealing disc C&P20P
4 --- Pins
5 --- Groove: this groove shows the position of the pin (4) for easier installation.
6 03165754-xx Cover assembly C&P20 P2
03110132‑xx Sealing gasket M4 (for cover)
6 Aperture ring, holding circuit and silencer
6.1 Replacing the aperture ring/holding circuit/sealing disc
46 Service Manual SIPLACE SpeedStar (C&P20 P2) 01/2019
Parts – compressed air operation
NOTICE
The SIPLACE C&P20P2 with compressed air mode had not been released by the time this
document was published.
Contact the SIPLACE Service team for details.
Fig.57: Holding circuit
1 03005123Sxx Holding circuit - vacuum unit
2 03046689-xx O-ring 50x1.5
3 03005120-xx Sealing disc for SIPLACE C&P20
4 --- Pins
5 03043707-xx Silencer assembly C&P20
See: 6.2 "Replacing the silencer (venturi mode only)" [}50]
Equipment and tools
T07 03078400-xx Torque Screwdriver ESD 1.0-5.0 Nm
T78 03090019-xx Torque interchangeable blades 2.5 mm, hexagonal
T98 03171857-xx Torque Allen swap blade 1.5 mm TX10
C03 03082092-xx Cleaning Wipe, KM-Wipe
C05 --- Isopropanol
C06 00352931-xx SIPLACE clean sticks
C11 03078517-xx ISOFLEX Topas 5051 50ml
T --- Tools for removing/fitting and calibrating the placement head, if needed
(see also the service manual for your machine)
6 Aperture ring, holding circuit and silencer
6.1 Replacing the aperture ring/holding circuit/sealing disc
Service Manual SIPLACE SpeedStar (C&P20 P2) 01/2019 47
Preparation
Remove the head from the machine. For details about removing and fitting the placement
head, refer to the service manual for your machine.
Fit the head on the head mount [03056231‑xx].
Make sure that the component sensor protective cap is fitted.
1.1.3 "Safety instructions for the component sensor" [}6]
Removal
NOTICE
Description example
The description uses the example of the aperture ring. The procedure for the holding circuit
is the same. Any relevant differences will be mentioned explicitly.
Fig.58: Dismantling the cover and aperture ring
Remove the fastening screw(1) (TX10)
and then take off the cover.
Remove the three screws(2) (TX10)
fastening the aperture ring.
Carefully lever the aperture ring off the
locating pins. Make sure that the O-ring
is not damaged.
Fig.59: Cleaning
Clean the seat of the aperture ring with
a cleaning cloth, coated with isopro-
panol.
 CAUTION!
Do not use compressed air for
cleaning!
.