00198608-02_SM_CP20P2_Kunde_EN - 第60页

7 Screwed joint 7.2 Replacing the screwed joint 60 Service Manual SIPLACE SpeedStar (C&P20 P2) 01/2019

100%1 / 90
7 Screwed joint
7.2 Replacing the screwed joint
Service Manual SIPLACE SpeedStar (C&P20 P2) 01/2019 59
Fig.80: Ground connections
Fasten the two ground connections(1)
with one screw each (TX6. M2x4,
torque 0.35Nm). Place a toothed disk
below and one above each ground con-
nection.
Follow the removal instructions in reverse order for further installation.
Also observe the installation instructions in the following section:
7.1 "Replacing the cover cap and grommet" [}55]
Observe in particular the torques specified!
7 Screwed joint
7.2 Replacing the screwed joint
60 Service Manual SIPLACE SpeedStar (C&P20 P2) 01/2019
8 Return unit
8.1 Replacing the return unit, cylinder, holder and driver lever
Service Manual SIPLACE SpeedStar (C&P20 P2) 01/2019 61
8 Return unit
8.1 Replacing the return unit, cylinder, holder and driver
lever
Parts
Fig.81: Return unit
1 03128518-xx Return unit assembly SIPLACE C&P20 P2
2 03007696-xx Return cylinder SIPLACE C&P20
3 03128516-xx Return cylinder holder SIPLACE C&P20 P2
4 03128517-xx Driver lever for return cylinder SIPLACE C&P20 P2
Equipment and tools
T07 03078400-xx Torque Screwdriver ESD 1.0-5.0 Nm
T19 00318673-xx Wire cutter electronic size 110
T47 00386253-xx Torque screwdriver ESD 0.4-1.0 Nm
T77 00386136-xx Torque interchangeable blades 2 mm, hexagonal
T78 03090019-xx Torque interchangeable blades 2.5 mm, hexagonal
T97 03075862-xx Torque Allen swap blade 1.5 mm TX8
T98 03171857-xx Torque Allen swap blade 1.5 mm TX10
T 00094020-xx Feeler gauge size 20 - 0.05 - 1.0 mm
C08 00308458-xx Cable ties B=2.5mm, L=102mm Panduit
T --- Tools for removing/fitting and calibrating the placement head, if needed
(see also the service manual for your machine)