8 Return unit 8.1 Replacing the return unit, cylinder, holder and driver lever Service Manual SIPLACE SpeedStar (C&P20 P2) 01/2019 61 8 Return unit 8.1 Replacing the return unit, cylinder, holder and driver lever Par…

100%1 / 90
7 Screwed joint
7.2 Replacing the screwed joint
60 Service Manual SIPLACE SpeedStar (C&P20 P2) 01/2019
8 Return unit
8.1 Replacing the return unit, cylinder, holder and driver lever
Service Manual SIPLACE SpeedStar (C&P20 P2) 01/2019 61
8 Return unit
8.1 Replacing the return unit, cylinder, holder and driver
lever
Parts
Fig.81: Return unit
1 03128518-xx Return unit assembly SIPLACE C&P20 P2
2 03007696-xx Return cylinder SIPLACE C&P20
3 03128516-xx Return cylinder holder SIPLACE C&P20 P2
4 03128517-xx Driver lever for return cylinder SIPLACE C&P20 P2
Equipment and tools
T07 03078400-xx Torque Screwdriver ESD 1.0-5.0 Nm
T19 00318673-xx Wire cutter electronic size 110
T47 00386253-xx Torque screwdriver ESD 0.4-1.0 Nm
T77 00386136-xx Torque interchangeable blades 2 mm, hexagonal
T78 03090019-xx Torque interchangeable blades 2.5 mm, hexagonal
T97 03075862-xx Torque Allen swap blade 1.5 mm TX8
T98 03171857-xx Torque Allen swap blade 1.5 mm TX10
T 00094020-xx Feeler gauge size 20 - 0.05 - 1.0 mm
C08 00308458-xx Cable ties B=2.5mm, L=102mm Panduit
T --- Tools for removing/fitting and calibrating the placement head, if needed
(see also the service manual for your machine)
8 Return unit
8.1 Replacing the return unit, cylinder, holder and driver lever
62 Service Manual SIPLACE SpeedStar (C&P20 P2) 01/2019
Preparation
Remove the head from the machine. For details about removing and fitting the placement
head, refer to the service manual for your machine.
Fit the head on the head mount [03056231‑xx].
Make sure that the component sensor protective cap is fitted.
1.1.3 "Safety instructions for the component sensor" [}6]
Removing the return cylinder
Fig.82: Pulling the cover off
Pull the cover(1) off the intermediate
distributor.
The cover is fixed by four press studs
on the stay bolts.
Fig.83: Dismantling the return cylinder
Remove the two screws(1) (TX10)
fastening the return unit and then care-
fully pull the return unit slightly out of
the head.