11 Software functions 11.5 Zero Point Calibration of Pressure Control Valve 88 Service Manual SIPLACE SpeedStar (C&P20 P2) 01/2019

11 Software functions
11.5 Zero Point Calibration of Pressure Control Valve
Service Manual SIPLACE SpeedStar (C&P20 P2) 01/2019 87
Fig.127: Sensors and Functions menu (using the example
of a CPP)
► Click the
button.
► Click the
button.
Fig.128: Set pressure to zero
► Select the placement heads affected.
► Click the
button.
► Go to the Specialized tab.
► Click on the Zero pressure adjust-
mentbutton.
► Click on the Calibrate piezo actuators
button.
► Click on theOptimize pressure regu-
lator button.
► Checking the embedded software and performing a download if needed (see LINK).