11 Software functions 11.5 Zero Point Calibration of Pressure Control Valve 88 Service Manual SIPLACE SpeedStar (C&P20 P2) 01/2019

100%1 / 90
11 Software functions
11.5 Zero Point Calibration of Pressure Control Valve
Service Manual SIPLACE SpeedStar (C&P20 P2) 01/2019 87
Fig.127: Sensors and Functions menu (using the example
of a CPP)
Click the
button.
Click the
button.
Fig.128: Set pressure to zero
Select the placement heads affected.
Click the
button.
Go to the Specialized tab.
Click on the Zero pressure adjust-
mentbutton.
Click on the Calibrate piezo actuators
button.
Click on theOptimize pressure regu-
lator button.
Checking the embedded software and performing a download if needed (see LINK).
11 Software functions
11.5 Zero Point Calibration of Pressure Control Valve
88 Service Manual SIPLACE SpeedStar (C&P20 P2) 01/2019