2.2 Model Change Operation Step 1 Program Change Operation Set the current pattern program, using the "PROGRAM CHANGE" window (submenu). Refer to "7. "PROGRAM CHANGE" Submenu in Sec- tion 5"…

2. Model Change Operation
2.1 Preparation for Model Change Operation
Step 1 Making a Backup Jig or a P.C.B. Holding Jig
Refer to "2. Specifications in Section 1" and "1. Specifications
of Backup Plate Making in Section 7" of this chapter and make
a P.C.B. backup jig or a P.C.B. holding jig required for the pro-
duction.
When the magnet support pins are used, it is not nec-
essary to make a P.C.B. backup jig or a P.C.B. holding
jig.
Step 2 Preparation for a Screen
Refer to "2. Specifications in Section 1" of this chapter and make
a screen required for the production.
Step 3 Creating a Pattern Program
Refer to "Section 2 Pattern Program in Chapter 1 of Volume 2"
and create a pattern program for the model to be produced.
2.1 Preparation for Model Change Operation
0211-005 Chapter 2 3-3 Tg0582-PM-D1

2.2 Model Change Operation
Step 1 Program Change Operation
Set the current pattern program, using the "PROGRAM
CHANGE" window (submenu).
Refer to "7. "PROGRAM CHANGE" Submenu in Sec-
tion 5" for the detailed information on how to perform
the program change operation.
Step 2 Product Change Operation
Perform the various kinds of product change operations, using
the "PRODUCT CHANGE" window (submenu).
Refer to "9. "PRODUCT CHANGE" Submenu in Sec-
tion 5" for the detailed information on how to perform
the product change operation.
(1) Adjustment of Magnet Support Pins and Attachment of
P.C.B. Backup Jig or Holding Jig
Adjust the position of the magnet support pins and attach
the P.C.B. backup jig or the P.C.B. holding jig prepared for
the model to be produced.
• Using the Magnet Support Pins
Consider the arrangement (balance) and insert them at the
points where they can support the P.C.B. securely during
printing and they should not get in the way of printing.
(a) When the magnet support pins are arranged
out of the P.C.B. position or in an unbalanced
condition, printing may not be performed cor-
rectly.
(b) When the magnet support pins are inserted,
using a template, refer to "3.1 Usage of Tem-
plate" for details.
• Using the P.C.B. Backup and Holding Jigs
Align the P.C.B. backup jig with the holes (dimensional po-
sitions) of the backup table and insert the positioning pins.
0211-005
Chapter 2 3-4 Tg0582-PM-D1
2.2 Model Change Operation

Fig. 2C2
••
••
• Using the Other Jigs
Consult our marketing department or sales agency for de-
tails.
Step 3 P.E.C. Test
Perform the P.E.C. recognition test for the P.C.B. to be produced,
using the "P.E.C. Recog. Test" tab sheet. (Operation Sequence:
"MAINT." Window (Main Menu) → "DEVICE TEST" Window
(Submenu) → "P.E.C. Recog. Test" Tab Sheet)
Refer to "7.1 "P.E.C. Recog. Test" Tab" (Section 6 of
Chapter 2) for details.
Step 4 Dual-Camera Auto Calibration
Correct the minute positional deviations of the P.E.C. and screen
recognition cameras, using the "2Cam. Auto Calibration" tab
sheet. (Operation Sequence: "AUTO OPN." Window (Main
Menu) → "PRODUCT CHG." Window (Submenu) → "2Cam.
Auto Calibration" Tab Sheet)
Refer to "9.8 "2 Camera Auto Calibration" Tab" (Section
5 of Chapter 2) for details.
Pick-Up Hole
Backup Jig
Holding Jig
Backup Table
Positioning Pins
0211-005 Chapter 2 3-5 Tg0582-PM-D1
2.2 Model Change Operation