1OM-1086-002.pdf - 第276页

4.5 "Cleaning Block" T ab 021 1-005 Chapter 2 6 - 19 Tg0582-PM-D1 *1 *2 4.5 "Cleaning Block" T ab This tab sheet can be used to perform the manual operation of the cleaning section. • Sheet Layout Whe…

100%1 / 355
[Screen Recog. Lamp (ON-OFF)] Button
When this button is pressed, the lighting for screen recognition is
turned on or off.
*2 Status
Displayed is how each unit is working.
4.4 "Recognition Block" Tab
0211-005 Chapter 2 6-18 Tg0582-PM-D1
4.5 "Cleaning Block" Tab
0211-005 Chapter 2 6-19 Tg0582-PM-D1
*1
*2
4.5 "Cleaning Block" Tab
This tab sheet can be used to perform the manual operation of the
cleaning section.
• Sheet Layout
When the [Cleaning Block] tab is pressed in the "MANUAL SUB-
SYSTEM" window (submenu), the following tab sheet appears.
Fig. 2F13 "Cleaning Block" Tab Sheet
• Sheet Composition
*1 Device Select Buttons
When a button is pressed, the background color turns blue, indi-
cating that the unit is selected.
When the [START] button on the front operation panel is pressed,
the selected unit starts moving. When the button is released, the
unit stops moving and is reset to the original position.
[Move Screen (Org.-Print Start Pos.)] Button
When this button is pressed, the screen frame starts moving be-
tween the origin and printing positions.
[Move Screen (Clng Start-End Pos.)] Button
When this button is pressed, the screen frame starts moving be-
tween the starting and end positions of cleaning.
[Paper Feed (ON-OFF)] Button
When this button is pressed, the cleaning paper is taken up.
[Cleaning Up/Down (UP-DOWN)] Button
When this button is pressed, the cleaning unit starts moving up or
down.
[Cleaning Vacuum (ON-OFF)] Button
When this button is pressed, solder paste is sucked through the
cleaning paper.
The blower unit (required for suction) is optional.
[Dispense Solvent (ON-OFF)] Button
When this button is pressed, cleaning solvent is discharged.
[Cleaning 1 Cycle (Cycle)] Button
When this button is pressed, the machine performs one-cycle op-
eration of cleaning.
*2 Status
Displayed is how each unit is working.
4.5 "Cleaning Block" Tab
0211-005 Chapter 2 6-20 Tg0582-PM-D1