5 .1 Basic Operations of Manual Alignment 5.1.1 Operation Procedure for Manual Alignment (1) Set the number of pulses per second in the "Move Speed" text box *4. Refer to "5.1.2 How to set parameters for &…

100%1 / 355
*5 Origin Monitor
Displayed are the kinds of methods to detect that the unit is lo-
cated at its origin, the availability, and the condition of the device.
Near Origin : A sensor is used to detect the linear motion of the
unit and this origin is regarded as a criterion to
determine whether or not the unit is located at its
origin.
Revol Origin : A slit cam is used to detect the revolution of the
ball screw and this origin is regarded as a criterion
to determine whether or not the unit is located at
its origin.
Animate : The rotational angle of the pulse motor is detected
and this origin is regarded as a criterion to deter-
mine whether or not the unit is located at its origin.
Origin Display
{ : The unit is zeroed.
× : The unit is not zeroed.
- : The method is not available.
*6 Movement Mode Select Buttons
Select one of these buttons to specify the movement mode of the
unit.
[Distance Assign.] Button
This button can be used to assign the moving distance by which
the unit moves through manual alignment operation.
[Move Pos. Assign.] Button
This button can be used to assign the position where the unit stays
after the subsequent manual alignment operation.
[Zeroing Opn.] Button
This button can be used to zero the unit.
*7 Setting Area for "Move Distance" and "Move Pos."
This area can be used to set the moving distance or position as-
signed in the above-described *6.
*8 Display Area for "Move Distance" and "Move Pos."
Displayed in this area are the numerical values that represent the
moving distance and position set in the above-described *7.
5. "MANUAL ALIGNMENT" Window (Submenu)
0211-005 Chapter 2 6-23 Tg0582-PM-D1
5.1 Basic Operations of Manual Alignment
5.1.1 Operation Procedure for Manual Alignment
(1) Set the number of pulses per second in the "Move Speed" text box
*4.
Refer to "5.1.2 How to set parameters for "Move Distance" and
"Move Pos."" for details.
(2) Press one of the movement mode select buttons *6.
(The background color turns blue.)
(3) Set parameters for "Move Distance" and "Move Pos." at the setting
area *7.
Refer to "5.1.2 How to set parameters for "Move Distance" and
"Move Pos."" for details.
(4) Press the [START] button on the front operation panel. The manual
alignment operation starts.
5.1 Basic Operations of Manual Alignment
0211-005 Chapter 2 6-24 Tg0582-PM-D1
5.1.2 How to set parameters for "Move Distance" and "Move
Pos."
Specify parameters for "Move Distance" and "Move Pos." (the distance
and position from the current position), using the unit "mm" or "pls
(pulses)".
The three methods (described below) are provided to set parameters
for "Move Distance" and "Move Pos.".
Fig. 2F16
Method 1: Setting with Pointer *1
(1) Press the point *1 with your finger and move it to the right or the
left. The numerical values in the "Move Distance" and "Move Pos."
text boxes *4 change accordingly.
(2) When you release your finger from the pointer at a position of the
scale box, the numerical values are set in accordance with the
pointer position.
Method 2: Setting with Spinner *2
(1) When the up arrow of the spinner *2 is pressed, the values in the
"Move Distance" and "Move Pos." text boxes increase in incre-
ments of one pulse (or # mm equivalent to one pulse). Pressing
the down arrow decreases the values in decrements of one pulse.
Method 3: Setting with Ten-Key Window
(1) When either one of the text boxes *3 is pressed, a ten-key window
opens.
Fig. 2F17
Refer to "2.3.1 Ten-Key Window in Section 4" for navigations in the
ten-key window.
5.1 Basic Operations of Manual Alignment
*4
*3
*2
*1
0211-005 Chapter 2 6-25 Tg0582-PM-D1