5.8 "PEC Rcg. X" Tab
This tab sheet can be used to perform the manual alignment operation
for the X axis of the P.E.C. recognition section.
• Sheet Layout
When the [PEC Rcg. X] tab is pressed in the "MANUAL ALIGN-
MENT" window (submenu), the following tab sheet appears.
Fig. 2F24 "PEC Rcg. X" Tab Sheet
• Sheet Composition
*1 Location
Displayed are the moving distance and the number of pulses that
represent the current location of the unit.
In the case of "P.E.C. Recog. X Axis", one pulse is equivalent to
"0.02 mm".
Refer to "5.1 Basic Operations of Manual Alignment" for the manual
alignment procedure.
5.8 "PEC Rcg. X" Tab
*1
0211-005 Chapter 2 6-32 Tg0582-PM-D1
5.9 "PEC Rcg. Y" Tab
*1
0211-005 Chapter 2 6-33 Tg0582-PM-D1
5.9 "PEC Rcg. Y" Tab
This tab sheet can be used to perform the manual alignment operation
for the Y axis of the P.E.C. recognition section.
• Sheet Layout
When the [PEC Rcg. Y] tab is pressed in the "MANUAL ALIGN-
MENT" window (submenu), the following tab sheet appears.
Fig. 2F25 "PEC Rcg. Y" Tab Sheet
• Sheet Composition
*1 Location
Displayed are the moving distance and the number of pulses that
represent the current location of the unit.
In the case of "P.E.C. Recog. Y Axis", one pulse is equivalent to
"0.02 mm".
Refer to "5.1 Basic Operations of Manual Alignment" for the manual
alignment procedure.
5.10 "PCB Backup" Tab
This tab sheet can be used to perform the manual alignment operation
for the P.C.B. backup axis.
• Sheet Layout
When the [PCB Backup] tab is pressed in the "MANUAL ALIGN-
MENT" window (submenu), the following tab sheet appears.
Fig. 2F26 "PCB Backup" Tab Sheet
• Sheet Composition
*1 Location
Displayed are the moving distance and the number of pulses that
represent the current location of the unit.
In the case of "P.C.B. Backup Axis", one pulse is equivalent to
"0.0067 mm".
Refer to "5.1 Basic Operations of Manual Alignment" for the manual
alignment procedure.
5.10 "PCB Backup" Tab
*1
0211-005 Chapter 2 6-34 Tg0582-PM-D1