1OM-1086-002.pdf - 第297页
6.1.3 Alignment Operation When the [Alignment (ST ART)] button is pressed in the "Inaccurate Posn. Correction" tab sheet (Fig. 2F28), the following window (Fig. 2F32) opens. Fig. 2F32 • • • • • Operation Proced…

••
••
• Movement to Specified Position
(1) Select the [Assign. Posn. Move (START)] button.
The window (Fig. 2F31) opens.
(2) Select the [X] and [Y] buttons entitled "Recog. Camera Move Posn.
Assign." and enter parameters using the ten-key pad.
(3) When the [START] button on the front operation panel is pressed,
Table X/Y moves to the recognition mark (foot pattern, etc.) lo-
cated at the specified position.
Fig. 2F31
(4) After the above-described operation, press the [CLOSE] button.
The previous window (Fig. 2F29) opens.
6.1 "Inaccurate Posn. Correction" Tab
0211-005 Chapter 2 6-39 Tg0582-PM-D1

6.1.3 Alignment Operation
When the [Alignment (START)] button is pressed in the "Inaccurate
Posn. Correction" tab sheet (Fig. 2F28), the following window (Fig. 2F32)
opens.
Fig. 2F32
••
••
• Operation Procedure
(1) When the table must be moved in the X direction or the screen in
the Y direction, specify the direction and speed of each movement.
(2) To move the table in the θ (theta) direction, press the [Angle] but-
ton and specify the direction and speed of the movement.
(3) When the [START] button on the front operation panel is pressed,
the table or the screen starts moving.
(4) Align the P.C.B. with the screen through the manual alignment op-
eration or using the screen recognition camera.
Saving the Settings for Inaccurate Position Correction
When the [Data Save] button in the "Inaccurate Posn. Correction" tab
sheet is pressed, the taught parameters are fed back as parameters for
"Prntng. Correction (Back)" and "Prntng. Correction (For.)" in the "Print"
data (Pattern Program Data).
Unit Return Operation
Select the [Unit Return Execute (START)] button in the tab sheet (Fig.
2F32) and press the [START] button on the front operation panel. The
original condition resumes.
6.1 "Inaccurate Posn. Correction" Tab
0211-005 Chapter 2 6-40 Tg0582-PM-D1

6.2 "Coordinate Teaching" Tab
This session describes how to teach the coordinates on the P.C.B. and
the screen, using the actually printed P.C.B. and the recognition cam-
era.
(a) The parameters set for "P.E.C. Recog. Posn." and "Screen
Recog. Posn." are reflected as those for the "PEC Recog"
and "Scr Recog" data (DATA EDIT).
(b) Use the coordiante teaching function only when there is
no accurate recognition data and data must be obtained
by measuring the product P.C.B. In this case, the correc-
tion of the subsequent P.C.B. coordinates is made based
upon the basic data (regarded as accurate coordinate data)
obtained by measuring only one piece of P.C.B. There-
fore, if there is a difference between the obtained (mea-
sured) coordinate data and the actually recognized accu-
rate coordinate data, the correction cannot be made pre-
cisely. In such a case, enter the accurate coordinate data
for the correction or change the inaccurate print correc-
tion data as tentative measures.
••
••
• Sheet Layout
When the [Coordinate Teaching] tab in the "TEACHING" window
(submenu) is pressed, the following tab sheet (Fig. 2F33) appears
inside the window.
Fig. 2F33
6.2 "Coordinate Teaching" Tab
*2
*1
*3
*4
*5
0211-005 Chapter 2 6-41 Tg0582-PM-D1