6.2.2 Editing of Recognition Mark Data When one of the mark buttons (*1) is pressed in the tab sheet (Fig. 2F33), the following tab sheet appears inside. Fig. 2F36 • This tab sheet enables you to change the parameters fo…

100%1 / 355
(6) Select the [Screen Recog. Mark 1 Coordinate Teaching (START)]
button and press the [START] button on the front operation panel.
The P.E.C. recognition camera moves to the coordinates on the
P.C.B. (the coordinates for screen recognition).
Perform the same manual alignment operation as "P.E.C. Recog-
nition Mark 1" on "Screen Recognition Mark 1".
(The coordinate data is displayed on the camera monitor (similar
to "(3)").)
(7) Select the [Screen Recog. Mark 1 Move (START)] button and press
the [START] button on the front operation panel.
The screen recognition camera moves to the coordinates that were
taught in "(6)".
After the end of the movement, select the [Recog. Test Exec.
(START)] button and press the [START] button to perform a recog-
nition test if necessary.
(8) Perform the same operation for "Screen Recognition Mark 2".
(9) Press the [Data Save] button to save the results of the teaching
operations.
This data is reflected on the P.E.C. recognition mark data of the
operation data.
(10) Select the [Unit Return (START)] button and press the [START]
button on the front operation panel. The original condition resumes.
6.2 "Coordinate Teaching" Tab
0211-005 Chapter 2 6-46 Tg0582-PM-D1
6.2.2 Editing of Recognition Mark Data
When one of the mark buttons (*1) is pressed in the tab sheet (Fig.
2F33), the following tab sheet appears inside.
Fig. 2F36
• This tab sheet enables you to change the parameters for the recog-
nition mark data such as "Mark Figure", "Mark Size", "Recog. Area
(mm)", "Algorithm", "Pol.", and "Level".
Refer to "Chapter 1 Programming" in "Volume 2" for the detailed
information on the recognition mark data.
6.2 "Coordinate Teaching" Tab
0211-005 Chapter 2 6-47 Tg0582-PM-D1
6.2.3 Manual Alignment Operation
When the [Eye Adjust] button is pressed in the "Coordinate Teaching"
tab sheet, the following tab sheet (Fig. 2F37) opens.
Fig. 2F37
[DIRECTION]
• Select the [ ▲ ], [ ▼ ], [
], or [ ] button to specify the direction of
the camera X and Y movement.
The indicated triangle marks show those of an image move-
ment on the camera monitor.
Note the direction of the actual camera unit movement be-
cause the unit moves in the reverse direction of the desig-
nated one.
[SPEED]
• The speed of the camera X and Y movement can be specified.
[HIGH] : Cameras X and Y move at high speed while the
[START] button is being pressed.
[LOW] : Cameras X and Y move at low speed while the
[START] button is being pressed.
[1 PULSE] : Cameras X and Y move in increments of 1 pulse
(0.01 mm) every time the [START] button is
pressed.
0211-005 Chapter 2 6-48 Tg0582-PM-D1
6.2 "Coordinate Teaching" Tab