1OM-1086-002.pdf - 第318页

7.1.2 Editing of Parameters for P .E.C. Recognition Monitor V arious parameters can be set for P .E.C. recognition test. (1) Mark Figure Press the [ ▼ ] button. The tab sheet changes as follows (Fig. 2F48). Some selectio…

100%1 / 355
7.1.1 Procedure for P.E.C. Recognition Test
(1) Position the P.C.B. to be tested on the table.
Set a P.C.B. to the dummy P.C.B. input location specified in the
"Operation Mode" tab sheet ("OPN. MODE" Window). After that,
select the [P.C.B. Clamp (START)] button and press the [START]
button
The P.C.B. is positioned and the camera moves to an area over
the P.E.C. recognition mark.
(2) Set various parameters for the P.E.C. recognition test.
Refer to "7.1.2 Editing of Parameters for P.E.C. Recognition Moni-
tor" for details.
(3) Press the [Camera X-Y Move] button. The "P.E.C. Recog. Camera
Move Opn. Scrn." window opens. Move the P.E.C. recognition cam-
era such that the P.E.C. recognition mark for the P.E.C. recognition
test enters inside the visual field of the camera (recognition range).
Refer to "7.1.3 Camera Movement Operation" for details.
(4) Select the [Recog. Test Exec. (START)] button and press the
[START] button on the front operation panel.
The machine performs the P.E.C. recognition test.
• After the recognition is completed normally, the camera moves
until the P.E.C. recognition mark is located at the center on the
camera monitor.
• When recognition is "NG (No Good)", a recognition error mes-
sage is issued.
The P.E.C. recognition test can be performed repeatedly.
The location of the P.E.C. recognition mark can be changed
for confirmation by moving the P.E.C. recognition camera
(manual alignment).
(5) When the [Unit Return (START)] button is selected and the [START]
button on the front operation panel is pressed, the shaft of the
P.E.C. recognition camera is zeroed and the P.C.B. returns to the
dummy P.C.B. input location.
7.1
"
P.E.C. Recog. Test
"
Tab
0211-005 Chapter 2 6-60 Tg0582-PM-D1
7.1.2 Editing of Parameters for P.E.C. Recognition Monitor
Various parameters can be set for P.E.C. recognition test.
(1) Mark Figure
Press the [ ▼ ] button.
The tab sheet changes as follows (Fig. 2F48). Some selection but-
tons appear, enabling you to specify a mark figure.
Fig. 2F48
When the fiducial mark of the P.C.B. to be produced is a P.C.B. mark,
press the [PCB Mark] button.
The window (Fig. 2F48) appears.
0211-05
Chapter 2 6-61 Tg0582-PM-D1
7.1
"
P.E.C. Recog. Test
"
Tab
When the fiducial mark is a through hole, press the [Thru. Hole] button.
The window (Fig. 2F49) appears.
When the fiducial mark is a pad mark, press the [PAD Mark] button.
The window (Fig. 2F50) appears.
Press the button that corresponds to the selected shape of the fiducial
mark.
As an example, when the shape of the fiducial mark is "Circle", press
the [CIRCLE] button.
Fig. 2F49 Fig. 2F50
(2) Mark Size D1 (mm), D2 (mm)
Press the data box of the label (parameter) to be selected. A ten-
key window opens. Enter a value, using the panel and press the
[ENT] button.
Press the [AC] button whenever it is necessary to clear the data.
(3) Recog. Area (mm)
Press the data box. A ten-key window opens. Enter a value, using
the panel and press the [ENT] button.
Press the [AC] button whenever it is necessary to clear the data.
(4) Pol.
Press the data box. Every time the data box is pressed, "Bright" is
changed to "Dark" or vice versa.
(5) Level
Press the data box. Every time the data box is pressed, the level
changes in this order ("HIGH" → "MDL." → "LOW").
(6) Gain and Level
To set each parameter, press the pertinent data box twice (not in
rapid succession). A ten-key window appears. Press the [AC] but-
ton to clear the data. Enter a value, using the ten-key window and
press the [ENT] button.
Or, press the [ ▲ ] or the [ ▼ ] button. Every time the [ ▲ ] button is
pressed, the value increases one by one. Pressing the [▼] button
decreases the value one by one.
Refer to "2.7" in Section 2 (Chapter 1 Programming in Vol. 2)
for the detailed description of each data item.
7.1
"
P.E.C. Recog. Test
"
Tab
0211-005 Chapter 2 6-62 Tg0582-PM-D1