7.1.2 Editing of Parameters for P.E.C. Recognition Monitor
Various parameters can be set for P.E.C. recognition test.
(1) Mark Figure
Press the [ ▼ ] button.
The tab sheet changes as follows (Fig. 2F48). Some selection but-
tons appear, enabling you to specify a mark figure.
Fig. 2F48
When the fiducial mark of the P.C.B. to be produced is a P.C.B. mark,
press the [PCB Mark] button.
The window (Fig. 2F48) appears.
0211-05
Chapter 2 6-61 Tg0582-PM-D1
7.1
"
P.E.C. Recog. Test
"
Tab

When the fiducial mark is a through hole, press the [Thru. Hole] button.
The window (Fig. 2F49) appears.
When the fiducial mark is a pad mark, press the [PAD Mark] button.
The window (Fig. 2F50) appears.
Press the button that corresponds to the selected shape of the fiducial
mark.
As an example, when the shape of the fiducial mark is "Circle", press
the [CIRCLE] button.
Fig. 2F49 Fig. 2F50
(2) Mark Size D1 (mm), D2 (mm)
Press the data box of the label (parameter) to be selected. A ten-
key window opens. Enter a value, using the panel and press the
[ENT] button.
Press the [AC] button whenever it is necessary to clear the data.
(3) Recog. Area (mm)
Press the data box. A ten-key window opens. Enter a value, using
the panel and press the [ENT] button.
Press the [AC] button whenever it is necessary to clear the data.
(4) Pol.
Press the data box. Every time the data box is pressed, "Bright" is
changed to "Dark" or vice versa.
(5) Level
Press the data box. Every time the data box is pressed, the level
changes in this order ("HIGH" → "MDL." → "LOW").
(6) Gain and Level
To set each parameter, press the pertinent data box twice (not in
rapid succession). A ten-key window appears. Press the [AC] but-
ton to clear the data. Enter a value, using the ten-key window and
press the [ENT] button.
Or, press the [ ▲ ] or the [ ▼ ] button. Every time the [ ▲ ] button is
pressed, the value increases one by one. Pressing the [▼] button
decreases the value one by one.
Refer to "2.7" in Section 2 (Chapter 1 Programming in Vol. 2)
for the detailed description of each data item.
7.1
"
P.E.C. Recog. Test
"
Tab
0211-005 Chapter 2 6-62 Tg0582-PM-D1

7.1.3 Camera Movement Operation
Select the [Camera X-Y Move] button.
The "P.E.C. Recog. Camera Move Opn. Scrn." window (Fig. 2F51)
opens.
Fig. 2F51
Manual Alignment Operation
Select the [Eye Adjust (START)] button for "Fiducial Mark #1" (First
P.E.C. Recognition Mark).
• Specify the direction with the [ ], the [ ], the [ ], or the [ ] button.
• Specify the speed with the [HIGH], the [LOW], or the [1 PULSE] but-
ton.
• Press the [START] button on the front operation panel and move the
P.E.C. recognition mark to the position in the recognition area where
the mark should be recognized.
While the [START] button on the front operation panel is being
pressed, the camera keeps on moving.
• Press the [CLOSE] button. The tab sheet (Fig. 2F47) resumes.
7.1
"
P.E.C. Recog. Test
"
Tab
0211-005 Chapter 2 6-63 Tg0582-PM-D1