T able 1A3-2 Switch Name Symbols Function Buzzer H 0 2 • Sounds when an error occurs. The machine is factory-adjusted as follows upon shipment. Buzzer Machine Condition CONTINUOUS Emergency Stop ON AND OFF Error The cond…

Table 1A3-1
Switch Name Symbols Function
OPERATION S03
• The selection key must be inserted to change over the
SET UP [OPERATION/SET UP] switch to the "OPERATION" or the
"SETUP" side.
The [OPERATION/SET UP] switch must be set to the "OP-
ERATION" side for automatic operation.
The switch can be changed over to "OPERATION" or "SET
UP" only when the machine is in the "STOP" mode.
When the switch is changed to the "SETUP" side,
the machine is set as follows.
(a) The red, yellow, green lamps of the light tower
will illuminate (initial setting of the machine upon
shipment).
(b) The following operations are prohibited regard-
less of the safety door condition (opened/closed).
Automatic Operation, P.C.B. Transfer (Cycle) Op-
eration, Zeroing Operation, Device Test, Unit Ad-
justment, and Teaching Operation
• When the [OPERATION/SET UP] switch
is set to the "SET UP" side, the interlock
function of the front safety door is deacti-
vated and it may cause critical injury to the
operator.
• Do not operate the machine with the [OP-
ERATION] switch in the "SET UP" side ex-
cept for the setup operations.
• Do not keep the selection key inserted un-
less necessary. The key shall be stored by
the person in charge.
START S05 • Starts automatic operation of the machine.
While the LED is ON, it indicates that the machine is run-
ning automatically.
It extinguishes when the [STOP] button is pressed during
operation.
STOP S07 • Stops automatic operation of the machine.
2.4 Operational Measures
0211-005 Chapter 1 1-9-1 Tg0582-PM-D1
Caution

Table 1A3-2
Switch Name Symbols Function
Buzzer H02 • Sounds when an error occurs.
The machine is factory-adjusted as follows upon shipment.
Buzzer Machine Condition
CONTINUOUS Emergency Stop
ON AND OFF Error
The condition of the machine corresponding to the
parameters specified for the buzzer can be
changed in the “MAC. SET-UP” window.
Refer to “2.2 “Tower Lamp/Buzzer Set-up” Tab” in
“Section 4 (Chapter 1 of Vol. 2)” for details.
2.4 Operational Measures
0211-005 Chapter 1 1-9-2 Tg0582-PM-D1

2.4.4 Touch Screen
Various types of operations become available by touching the operation
buttons and tabs on the touch screen.
Fig. 1A13
••
••
• Operation Procedure
Press the center of an operation button with your finger.
The touch-sensitive regions of the touch screen reacts to a
force of 49 Ncm
2
(approx. 5 kgf/cm
2
) or less.
Do not press the screen with an excessive force.
2.4 Operational Measures
• Since the touch screen uses the molecules in liquid
crystals, handle it like glass.
Do not apply strong pressure to the touch screen.
Try not to touch the screen except for input opera-
tions.
• The surface of the touch screen is damaged easily,
does not rub, and does not press by using the pen
and the driver, etc.
• The touch screen is not a water-proof and encapsu-
lated type. Avoid dust, water droplet, oil droplet, and
metal pieces.
Especially, when metal pieces or combustible mate-
rial is mixed into the machine, it may lead to fire igni-
tion.
CAUTION
Tab
Operation
Button
Operation
Button
0211-005 Chapter 1 1-10 Tg0582-PM-D1